IMPORTANT!
The sintering of Cercon ht in third-party sintering furnaces is done at the user's own responsibility and risk.
DeguDent can accept no responsibility for any kind of damage caused by the sintering of zirconia materials in
third-party furnaces, including but not limited to damage to or damage caused by the sintered objects such as
abutments, crowns or bridge frameworks.
Additional notes:
The programming you use for your sintering furnace should be analogous to the DeguDent sintering programs.
General Sinter programs Cercon ht all shades
Material:
Cercon ht, all shades
Sinter program for bridge
frameworks up to 8 units
Sinter program for bridge
frameworks for 9 or more units
Speed-Sinter program für bridge
frameworks up to 6 units
1) Room temperature
Material:
Cercon ht, all shades
Sinter program for bridge
frameworks up to 8 units
Sinter program for bridge
frameworks for 9 or more units
Speed-Sinter program für bridge
frameworks up to 6 units
1) Room temperature
Material:
Cercon ht, all shades
Sinter program for bridge
frameworks up to 8 units
Sinter program for bridge
frameworks for 9 or more units
Speed-Sinter program für bridge
frameworks up to 6 units
1) Room temperature
Cercon® ht Instructions for Use
Start-
Ramp
Temp. 1
Temp.
time
°C
min
°C
RT
40
900
1)
RT
120
860
1)
RT
90
1540
1)
2)
2) valid for closed sinter bowls, otherwise 1520°C
Start-
Ramp
Temp. 1
Temp.
time
°C
°C/min
°C
RT
22
900
1)
RT
7
860
1)
RT
17
1540
1)
2)
2) valid for closed sinter bowls, otherwise 1520°C
Start-
Ramp
Temp. 1
Temp.
time
°C
°C/h
°C
RT
1320
900
1)
RT
420
860
1)
RT
1020
1540
1)
2)
2) valid for closed sinter bowls, otherwise 1520°C
Holding
Ramp
Temp. 2
time
time
min
min
°C
0
55
1500
0
320
1500
35
20
1150
Holding
Ramp
Temp. 2
time
time
min
°C/min
°C
0
11
1500
0
2
1500
35
18
1150
Holding
Ramp
Temp. 2
time
time
h:min
°C/h
°C
00:00
660
1500
00:00
120
1500
00:35
1080
1150
Holding
Cooling
time
min
145
With closed furnace cooling
down to 200 °C
120
With closed furnace cooling
down to 200 °C
0
Gradual opening of the furnace
within 35 Min down to 200 °C
Holding
Cooling
time
min
145
With closed furnace cooling
down to 200 °C
120
With closed furnace cooling
down to 200 °C
0
Gradual opening of the furnace
within 35 Min down to 200 °C
Holding
Cooling
time
h:min
02:15
With closed furnace cooling
down to 200 °C
02:00
With closed furnace cooling
down to 200 °C
00:00
Gradual opening of the furnace
within 35 Min down to 200 °C
67