Additional Notes - Dentsply Sirona Cercon base Instrucciones De Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

For these reasons, we cannot grant general approval for the use of third-party furnaces for sintering two-piece
abutments (mesostructures) and crown and bridge frameworks made of Cercon® base, Cercon® ht and
Cercon® xt We will, how ever, open the system technically for the use of furnaces of third-party furnaces only
on condition that the following requirement are met:

Additional notes:

The programming you use for your sintering furnace should be analogous to the Dentsply Sirona sintering programs
General Sinter programs Cercon® base, Cercon® ht and Cercon® xt all shades
Material:
Sinter program for bridge frameworks up to
8 units ( Cercon® base, Cercon® ht) and bridge
frameworks up to 3 units ( Cercon® xt)
Sinter program for bridge frameworks for
9 or more units ( Cercon® base, Cercon® ht)
Speed-Sinter program for bridge frameworks
up to 6 units ( Cercon® base, Cercon® ht) and
for bridge frame works up to 3 units ( Cercon® xt)
Material:
Sinter program for bridge frameworks up to
8 units ( Cercon® base, Cercon® ht) and bridge
frameworks up to 3 units ( Cercon® xt)
Sinter program for bridge frameworks for
9 or more units ( Cercon® base, Cercon® ht)
Speed-Sinter program for bridge frameworks
up to 6 units ( Cercon® base, Cercon® ht) and
for bridge frame works up to 3 units ( Cercon® xt)
Material:
Sinter program for bridge frameworks up to
8 units ( Cercon® base, Cercon® ht) and bridge
frameworks up to 3 units ( Cercon® xt)
Sinter program for bridge frameworks for
9 or more units ( Cercon® base, Cercon® ht)
Speed-Sinter program for bridge frameworks
up to 6 units ( Cercon® base, Cercon® ht) and
for bridge frame works up to 3 units ( Cercon® xt)
1) Room temperature
2) valid for closed sinter bowls, otherwise 1520 °C
6
Start-
Ramp
Temp.
time
Temp. 1
°C
min
°C
RT
40
900
1)
RT
120
860
1)
RT
90
1540
1)
2)
Start-
Ramp
Temp.
time
Temp. 1
°C
°C / min
°C
RT
22
900
1)
RT
7
860
1)
RT
17
1540
1)
2)
Start-
Ramp
Temp.
time
Temp. 1
°C
°C / h
°C
RT
1320
900
1)
RT
420
860
1)
RT
1020
1540
1)
2)
Holding
Ramp
time
time
Temp. 2
min
min
°C
0
55
1500
0
320
1500
35
20
1150
Holding
Ramp
time
time
Temp. 2
min
°C / min
°C
0
11
1500
0
2
1500
35
18
1150
Holding
Ramp
time
time
Temp. 2
h : min
°C / h
°C
00 : 00
660
1500
00 : 00
120
1500
00 : 35
1080
1150
Holding
time
Cooling
min
With closed furnace
145
cooling down to 200 °C
With closed furnace
120
cooling down to 200 °C
Gradual opening of the furnace
0
within 35 Min down to 200 °C
Holding
time
Cooling
min
With closed furnace
145
cooling down to 200 °C
With closed furnace
120
cooling down to 200 °C
Gradual opening of the furnace
0
within 35 Min down to 200 °C
Holding
time
Cooling
h : min
With closed furnace
02 : 15
cooling down to 200 °C
With closed furnace
02 : 00
cooling down to 200 °C
Gradual opening of the furnace
00 : 00
within 35 Min down to 200 °C
Tabla de contenido
loading

Este manual también es adecuado para:

Cercon htCercon xt

Tabla de contenido