variants). Ensure that the connection to the
hose is secure and airtight. The connection
must not be loosened by the therapy pressure.
If you want to detach the mask temporarily
from the hose, pull the rotating sleeve off the
elbow.
3.5 Gel-filled mask components
On JOYCE GEL vented and JOYCE GEL
non vented, the forehead cushion and the
mask cushion are gel-filled as standard. Gel
forehead cushions and gel mask cushions are
also available as replacement parts for other
JOYCE variants.
Caution!
Gel-filled mask components are highly sensi-
tive components. Always handle them with
care to prevent deformation and damage.
3.6 Therapy pressure ranges
The individual JOYCE mask variants are each
available for a particular therapy pressure
range (see "7. Scope of supply" on page 17):
– 4-30 hPa: JOYCE vented
JOYCE non vented
– 4-40 hPa: JOYCE vented 40 hPa
JOYCE non vented 40 hPa
JOYCE GEL vented
JOYCE GEL non vented
The JOYCE masks for the therapy pressure
range 4 - 30 hPa have a soft mask cushion, the
JOYCE masks for the therapy range 4 - 40 hPa
have a harder mask cushion or a gel mask
cushion (gel-filled variants).
The harder mask cushion for the therapy
pressure range 4 - 40 hPa is marked with the
number "40".
The soft (up to 30 hPa) and harder (up to 40
hPa) mask cushion and the gel-filled mask
cushion (gel variants) are also available as
individual replacement parts to enable you to
adapt your mask to changed therapy
requirements.
14
Operation
EN
3.7 Ports for pressure
measurement (Fig. C)
JOYCE masks are fitted with two ports that
can be used to measure pressure or to feed
in oxygen.
Caution!
• Oxygen therapy can have side-effects if
incorrectly administered or used in the
wrong dosage. Only carry out this sort of
treatment if prescribed by a physician.
• When carrying out oxygen therapy, strictly
follow the instructions for use of your O
system and your therapy device.
When the pressure measurement ports are
not in use, always close them with the cap
provided. Otherwise air will escape from the
ports and the therapy pressure will not be
reached.

3.8 Compatible devices

Therapy devices
JOYCE masks can be combined with all
devices designed for carrying out the
therapies described under "Intended Use".
Note that if unsuitable device combinations
are used, the actual pressure in the mask may
not correspond to the therapy pressure you
have been prescribed.
This may also happen even if the correct
pressure is indicated on the therapy device.
Have your device combination adjusted by a
physician or distributor so that the pressure
in the mask corresponds to your therapy
pressure.
Air humidifiers
JOYCE masks can be used with either cold-air
or warm-air humidifiers.
Never set the humidification level so high
that condensation forms in the air hose.
Follow the instructions for use of your
humidifier and therapy device.

3.9 After use

1.Unhook one of the lower headgear clips
from the mask and remove the mask.