G G
B B
FOTOCOSTA
Connect the fotocosta to terminals 8-10.
As the fotocosta is operated, the movement reverses.
12VDC CONNECTION OF THE WARNING LIGHT LED
(TO SIGNAL THE AUTOMATION IS OPEN)
Connect the warning light to terminals D- and 7 (max. 6 watt).
The signal is given when the automation is open, partly open or, in any
case, not totally closed.
230V 40W BLINKER
If you want the Blinker to start three seconds before the motor does,
position "Dip 6 on mode ON".
C
ARATTERISTICHE TECNICHE
Umidità
Tensione di alimentazione
Frequenza
Miicrointerruzzioni di rete
Potenza gestibile all'uscita del motore
Carico max uscita lampeggiatore
Assorbimento max scheda (esclusi accessori) 30 mA
Corrente disponibile ai morsetti D+D-
Grado di protezione
Peso apparecchiatura
Ingombro
E
LECTRONIC SAFETY DEVICES
The limit switches and the motor of NORMAL are already connected to
the electronic control panel.
Only one push-button panel, the photocells, the blinker and, of course,
the power voltage need to be wired.
Persons and things shall be protected against any possible crushing
caused by unwanted commands: to this purpose you must install at
least a couple of photocells or a fotocosta under the boom.
To further prevent vandalistic acts, you can avail yourself of the
´column with magnet´, that can block the boom in its closed position).
For information about the connections or technical data of accessories,
follow the relevant instruction books.
M
AINTENANCE
To be undertaken only by specialized staff after disconnecting
power supply.
After every 20.000 cycles check boom balance, the tightness of the
release knob and of the boom holding attachment, and the wear on the
mechanical stops.
Grease the bearings of the boom carrier shaft and the threaded spring
guide bar.
< 95 % senza
condensazione
230 Vac ±10%
50/60 Hz
20 ms
736 W
40 W - 250 Vac
cosƒi=1
0,8A ±15% - 12Vdc
IP54
0,8 Kg