REACTION TIME

The push buttons have a default short reaction time (65ms). There is possibility to maintain the push button pressed for 1, 2 or 3 seconds
until they are considered as being closed.
Follow this procedure:
1. Set the hexadecimal rotary switches on one off following positions:
Address
F0
F1
2. Press now (min. 3 seconds) every push button you would like to assign this reaction time to.
After release the connected LEDs parallel to the push buttons will turn on in different ways to indicate the chosen reaction time.
Very fast blinking: 65ms
Fast blinking: 1 second
Slow blinking: 2 seconds
Continuous: 3 seconds
These reaction times are saved into the module (even in case of a power failure).
3. Exit the mode by resetting the address at the original value of the chosen module address.
Reaction time
65ms
1 second
Address
Reaction time
F2
2 seconds
F3
3 seconds