Checking the air outlet filter
-
Turn the dry vacuum cleaner upside
down, then unscrew the screws (27 Fig.
17) and remove the filter (28 Fig. 18).
-
Remove the filter sponge (29 Fig. 19) from
the frame and clean it with a blast of air.
The filter sponge can be washed in warm
water and must only be replaced once it is
completely dry. If it is too dirty, replace it.
-
Reassemble everything proceeding in re-
verse order compared to disassembly, posi-
tioning the filter (28 Fig. 20) correctly, ensur-
ing the two arrows coincide (29 Fig. 20).
PROBLEM
The vacuum cleaner does
not work.
Suction is not satisfactory.
(Orange light on).
Cleaning the appliance body
-
Clean the appliance body using a cloth
dampened with water or mild detergent.
Do not wash the appliance using jets of wa-
ter.
Pack of 10 paper filter bags Code 6582030
Cartridge filter
HEPA filter
CAUSE
Switch not pressed.
Not plugged in.
No current.
Paper bag full.
Filter elements clogged.
Accessories or tubes
clogged.
EN - 3
DANGER:

SPARE PARTS

SOLUTION
Press the switch.
Insert the plug into the
socket.
Check the power line.
Replace the dust bag.
Clean the filter elements.
Check and clean the hose
and the suction tool.