GYS SPOT LIFT Manual De Instrucciones página 12

Ocultar thumbs Ver también para SPOT LIFT:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 19
SAFETY MEASURES
- The SPOT LIFT must be used by appropriately trained people, authorised to use it and that have been made aware of
the contents of this manual. The latter must be read attentively before using the SPOT LIFT. It is forbidden to lift people
with this tool.
- A safety perimeter must be defined in which no one must be present during the lifting operation (2m around the
vehicle to allow escape if necessary).
- Check the load in order to avoid the bad positionning of the jack or the vehicle. To rectify, lower the the load and
reposition the jack correctly on the vehicle.
- Before any load lifting, make sure that both the fork and product are stable
- Once the vehicle is lifted, always put the safety axis in the column to maintain the charge.
- Do not put the pads in an area with a plastic coating.
- Verify that the air pressure input is between 6 and 8 bar.
- After the working session, lower the vehicle to the ground to prevent the SPOT LIFT from sustaining a full load during
extended periods.
- The vehicle's maximum weight must not exceed 2500 kilos.
- The device must not be used in a potentially explosive atmosphere or near heat sources.
- It is forbidden to use the device on a boat/ship for stability reasons.
ANOMALIES, CAUSES, SOLUTIONS
The table below indicates the anomalies that could arise when the product is in use. If the problem is not listed in the
table below, stop using the product and contact your distributor for further advice.
ANOMALIES
The device stops while lifting
The commands are actionned but the
jack does not lift
The jack lowers by itself
Pump's oil leak
Hosepipe's oil leak
Connectors' oil leak
12
There are obstacles in the lifting
column
Excessive load
Compressed air exhaust silencer
obstructed
The air supply is insufficient
Pump's discharge valve is clogged
Seals are worn out
Hosepipe worn out or cracked
Connector worn out or cracked
If the hydropneumatic pump fails, it is dangerous to replace it with an alternative product. Using
another pump can lead to serious accidents and/or product deterioration. Repairing the pump and
the jack can only be performed by qualified GYS personnel.
SPOT LIFT
CAUSES
SOLUTIONS
Lower the load, cut off the air supply
and remove the obstacle.
Check the vehicles's weight
and observe the manufacturer's
instructions.
Clean or replace the compressed air
exhaust silencer.
Check that the air pressure is
comprised between 6 and 8 bar.
Contact the manufacturer before
proceeding to any repair
Contact the manufacturer before
proceeding to any repair
Replace the hosepipe
Replaced the cracked connector
EN