6) Technical characteristics
All technical specifications refer to a temperature of 20°C.
Electronic control unit
Power supply
Maximum motor power
Operating temperature
Dimensions / weight
Protection class
Blade swivelling time
Time taken by manoeuvre
Radio receiver
Frequency
Coding
N°. of transmitter that can be memorised
Range of the transmitters
* The capacity of the transmitters is strongly influenced by other devices with continuous transmissions which operate at the same frequency.
These include alarms, headphones, etc... which interfere with the control unit receiver.
Nice S.p.a reserves the right to make changes to its products at any time as it deems necessary
Declaration of conformity
Nice S.p.a. via Pezza Alta, 13 Rustignè Oderzo (TV) ITALY
R&TTE 1999/5/CE
date
17-05-2004
: 230Vac (+10-15%) 50Hz
: 500W / 400VA
: -20 ÷ 50 °C
: 98 x 26 x 20 / 45g
: IP55 (container undamaged)
: 2-3 seconds with "man present" mode
: From 4 to 250 seconds (factory setting approx. 150 sec.) after swivelling time has run out
: 433.92MHz
: FLO (fixed code), FLOR (rolling code) SMILO (rolling code)
: 30 (max. 3 weather sensors)
: estimated 150 m outdoor, 20 m indoor. *
declares that the product: "mindy TT1V" complies with the essential safety provisions of Directives:
N°: 189/TT1V Rev 0
General Manage
Lauro Buoro
GB