PREPARING THE
APPLIANCE
Mounting accessories basket
-
Insert the basket (57) from the upper part
of the handle (58) and lock it in the de-
sired position by inserting the two lower
pins (59) into the holes (60) arranged on
the pipes of the jumper(58).
-
The basket has two fixing positions.
-
Maximum permissible weight: 5Kg.
Assembling the hoses
-
Turn the pipe (13 Fig. 2) so that the pin
(14 Fig. 2) is positioned upward.
-
Move the lever (15 Fig. 2) clockwise and
hold it in position then introduce, until the
limit the sealing ring (13 Fig. 2) of the suc-
tion tube into the orifice (16 Fig. 2) pre-
sent on the frame.
-
Release the lever (15 Fig. 2) and check
that the hose is connected correctly.
-
To release the sleeve (13 Fig. 3) move
the lever (15 Fig. 3) clockwise then pull
the sleeve outwards (13 Fig. 3).
-
Lift the cover (17 Fig. 4) and plug (18 Fig.
4) into the socket up to the limit.
-
Lower the cover (17 Fig. 5) making the
pin snap (19 Fig. 5) in the hole (20 Fig. 5).
WARNING:
Before using the appliance check that
the tube slides linear and has no tight
bends; always guide the tube with one
hand
close to the ergonomic handle
when turning.
Rigid pipe assembly for washing carpets
or floors
After connecting the suction hose to the out-
let the drum, do as follows:
-
Check that the lever (21 Fig. 6) is in verti-
cal position and that is in position "A" as in
the figure.
-
Attach to the ergonomic handle of the
hose (22 Fig. 6) the first extension (2 Fig.
6).
-
Lock the rigid extension (2 Fig. 6) by turn-
ing the lever (21 Fig. 6) at 45° and then
move the lever (21 Fig. 6) to position "B" to
block the accidental release of the exten-
sion.
-
Attach to the first extension (2 Fig. 6) the
second extension (2a Fig. 7) and lock as
described above for the first extension.
-
Attach the second extension (2a Fig. 7)
the floor nozzle (12 Fig. 7) and secure it
using the lever (23 Fig. 7) by turning it
45°.
NOTE:
To release the tubes act inversely than for
the coupling operation.
Nozzle assembly for washing windows
After connecting the suction hose to the out-
let the drum, do as follows:
-
Check that the lever (24 Fig. 8) is in ver-
tical position and then attach to the er-
gonomic handle (22 Fig. 8) the windows
squeegee (5 or 12 Fig. 8) and lock it by
turning the lever (24 Fig. 8) to 45°.
Filling the tank (if present)
DANGER:
Before filling the tank make sure the
unit is turned off and the power plug is
disconnected.
-
Remove the cap (25 Fig. 9) and pour in
the tank (26 Fig. 9) about 8 liters of water.
NOTE:
It is advisable to fill the tank with 50% tap
water and 50% de-mineralized water or alter-
natively demineralized water.
This is to prevent the formation of limescale
in the boiler.
-
Replace the cap (25 Fig. 9).
Filling the boiler (for models without tank)
DANGER:
Before filling the boiler make sure the
unit is powered down, the power plug is
disconnected and that the boiler is cold.
ENGLISH - 3