PREPARING
THE APPLIANCE
-
Remove the plug (1 Fig. 1) for the evacu-
ation pump.
-
Release the levers (2 Fig. 2) and remove
the cover head (3 Fig. 3) complete with
the motor unit.
-
Check that there is a mesh filter (4 Fig. 4)
in the tank.
-
If the mesh filter (4 Fig. 4) is not present,
install it as follows:
Slide the plastic ring (5 Fig. 5) of the bag
into the orifice (6 Fig. 5) until you hear the
click of the lock ring in the groove (7 Fig.
5).
-
Place the cover head back on and lock it
using the levers (2 Fig. 2).
-
Insert the plug (1 Fig. 1) int the socket.
-
Insert, as far as possible, the sleeve (8
Fig. 6) of the suction hose into the nozzle
(9 Fig. 6) on the drum.
-
To release the sleeve (8 Fig. 6) press and
hold the button (10 Fig. 6) then, pull the
sleeve outwards (8 Fig. 6).
-
Connect the hose (11 Fig. 7) with the ex-
tension (12 Fig. 7).
-
Join the two rigid extensions (12-13 Fig.
8) aligning the reference points (14-15
Fig. 8).
-
Attach the chosen accessory to the rigid
extension (13 Fig. 9) (liquid suction noz-
zle or flat nozzle).
-
Connect a flexible hose to the 30-mm dis-
charge outlet (16 Fig. 10).
USING THE APPLIANCE
-
The appliance is equipped with wheels
and can be pushed with the handle (17
Fig. 11).
-
It should be lifted by two people using the
handles (18 Fig. 11) located in the lower
part of the large handle.
Starting up the appliance
-
Insert the plug (19 Fig. 12) in the power
socket and check that the plug (1 Fig. 1)
powering the evacuation pump is correct-
ly inserted.
-
Depending on the power required it is
possible to start only one motor by press-
ing the switch (20 Fig. 13) on "I" or both
switches (20-21 Fig. 13) if a greater suc-
tion force is required.
NOTES:
The evacuation pump is operated by a start
float located inside the tank; to ensure that
the pump operates and cools correctly, it
starts when the water level reaches a height
of 1 cm in the tank and stops when the level
drops below that height.
NOTES:
In case the recovery tank fills up, there is an
increase of noise and the device no longer
vacuums, then turn off the appliance and
empty the tank.
ENGLISH - 2
www.ghibliwirbel.com
Professional Cleaning Machines Since 1968