www.ghibliwirbel.com
Professional Cleaning Machines Since 1968
Checking the operation of the electri-
fied hose
-
Check that the tube (1 Fig. 1) is not ru-
ined and that the present electrical con-
trols work properly ( vacuum start and
steam distribution).
-
If you encounter failures, do not use the
hose and contact an authorized service
center for its control.
Boiler water discharge
-
If the machine is not used for a few days
it is advisable to drain the water in the
boiler.
-
Place the appliance on a grill to drain and
turn it on its side; unscrew the cap (56
Fig. 30).
-
Reposition the unit to its original position
and let the water inside drain completely.
-
Refit the cap (56 Fig. 30).
Operations to be carried out as nec-
essary
Replacing the fuse
If the switch (33 Fig. 11) pushed in "I" position
does not light, it is necessary to check the
fuse (57 Fig. 11).
WARNING:
Replace the blown fuse with one of the
same amperage.
Fuse = 500 mA
DANGER:
If the fuse blows continuously, contact an
authorized service center for the control
of the equipment.
Replacement of O-rings
If during use you encounter vapor losses
from the accessories you need to replace the
O-rings (46 Fig. 20), by receiving them from
the manufacturer's spare parts service.
DANGER:
Do not use the appliance with steam
emissions from accessories; scalding
danger!
SPARE PARTS
NOTE:
Use only original spare parts supplied by the
manufacturer.