DESCRIPTION
L
N
30VDC
Motor MASTER
Motor SECOND
To check correct polarity refer to section basic setting and
functionality P1+P2+P3
24V/150mA
Motor1
BRN
GRN
WHT
YEL
Motor2
BRN
GRN
WHT
YEL
Light Contact
PED
COM
STOP
Key symbol
COM
PHOTO3
PHOTO2
PHOTO1
COM
EDGE
8.2kOhms
RADIO
Antenna symol
E-lock symbol
INPUT 24VAC
Transformer 230VAC
250V/2A
FUNCTIONALITY OVERVIEW OF THE PUSH BUTTONS P1, P2, & P3
Button
Function
P1+P2+P3
Manual operation. The gate wings can be moved electrically in a manual mode. Activate Function: Push P1+P2+P3
simultaneously. The LED DGN starts to flash as long as feature is activated. Button P1 operates Motor1. Button P2 operates
Motor2. Deactivate: Wait for 20 seconds or disconnect logic board power. If wings close at first reverse wires red and blue.
P1
For automatic programming of the automatic travel distance limits of the gate.
P1 + P2
For the advanced programming of the travel distance limits of the gate
P2 + P3
Electric lock delay time
P1 + P3
Wing delay adjustment.
P2
Automatic closing time. Requires also P3 to confirm.
P3
Software-reset to factory defaults. Push & hold for 10 seconds. Does not reset the remote control memory (see section "radio").
Radio jumper + P1 Programming Remote for Channel 1
Command for both motors (wings)
Radio jumper + P2 Programming Remote for Channel 2
Command for single motor (Motor1).
FUNCTION
connector L 230V supply
connector N 230V supply
connector for a battery kit +/-
CM475 + 041ADBL-0115
motor 1 (master opens first) red/blue
motor 2 (Second opens second)
red/blue
flashing light (accessory)
MASTER
brown cable
green cable
white cable
yellow cable
SECOND
brown cable
green cable
white cable
yellow cable
gate monitor/ yard lighting
connection for emergency stop or
negative pole
stop switch
key switch
negative pole
photocells 3 (open)
photocells 2 (close & open)
photocells 1 (close)
negative pole
safety edge with 8.2KOhms
connection for radio module
connection for antenna 75Ohms
connection for E-lock control board
24V power input from transformer.
can be connected with any polarity.
230V supply to transformer. Can be
connected with any polarity.
fuse 250V/2A (2x included)
DESCRIPTION OF LED´S (LIGHT EMITTING DIODE)
DESCRIPTION
COLOUR
Stop
green
Edge
green
"Key symbol"
red
PED
red
PHO 1
red
PHO 2
red
PHO 3
red
LEARN
yellow
DGN
red
CH1
red
CH2
red
STATUS
Stop Switch
ON: Stop Active
OFF: OK
(Requires wire bridge if no
switch is connected)
Safety Edge 8.2KOhm
ON: Activated
OFF: OK
(Requires 8.2KOhm resistor if not used)
Key-switch 2-wing opening
ON: Activated
OFF: OK
Key-switch 1-wing opening
ON: Activated
OFF: OK
Photocell 1 (close)
ON: OK, photocell
connected (no problem)
OFF: No photocells connected
Dimming: Photocell blocked,
function & diagnostic is
blinking
Photocell 2 (open & close)
(Refer to photocell 1)
Photocell 3 (open)
(Refer to photocell 1)
Programming indicator
ON: (flashing)
programming is active
OFF: off
Diagnostic, Refer to page 15,
section: Indication of diagnostic blinks
Remote control
programming 2-wing opening
ON: New remote can be
programmed
OFF: off
Refer to section RADIO
for programming details.
Remote control programming
1-wing opening (Refer to CH1)
loading