Selecting Beeper Volume
The scanner emits a short beep when it successfully reads a bar code. The
volume of the beep is changed by scanning one of the beeper volume bar codes
in the LS 7708 Product Reference Guide, or by using the Volume Control &
Wakeup button on the front of the scanner as follows:
1. Press and hold the button for approximately five seconds. The scanner
cycles through three settings (low, medium, high), emitting a two-beep
tone at each setting.
2. To select a particular setting, release the button after the desired 2-beep
tone is heard.
Beeper Definitions
The scanner communicates with the user by emitting different beeper
sequences and patterns. See the Standard Beeper Definitions table for beeper
sequences that occur during both normal scanning and while programming the
scanner.
Beeper Sequence
Standard Use
3 short high beeps
Short high beep
4 long low beeps
5 low beeps
Hi-hi-hi-lo beep
Code 39 Buffering
Hi-lo beep
Standard Beeper Definitions
Power up.
A bar code symbol was decoded (if decode beeper is
enabled).
A transmission error was detected in a scanned
symbol. The data is ignored. This occurs if the scanner
is not properly configured. Check option setting.
Conversion or format error.
RS-232 receive error on RS-232 host or RS-232
auxiliary port.
New Code 39 data was entered into the buffer.
Indication