Automatic Switch
AS888
Part No. : 34-888
US: 26014
The automatic
switch protects
electrically operated
pumps and gives fully
automatic operation.
The switch is made of corrosion
resistant materials.
Max size: Width 75 mm, length
115 mm, height 95 mm.
Installation
Before installing float switch
AS888 form two ≈ 15 cm loops
of the wire and lock them in the
grooves in the base plate. Thus the
automatic float switch can move
with a minimum of resistance.
On a plate surface
Fix with two screws.
Ball at rest, switch in off mode.
Original instructions
OFF
ON
Water raises switch, ball rolls back,
switch snaps on.
With SPX FLOW Johnson Pump
submersible bilge pumps
SPX FLOW Johnson Pump
submersible bilge pumps have a
T-slot on the housing or mounting
bracket. You may simply push the
switch into place onto the pump.
If you wish, a small drop of
water-proof adhesive will lock the
switch on the T. Screws are
recommended for fastening the
switch only if your pump is not
equipped with a T-mount.
AS888 should always be
installed in parallel to the keel with
the floating body directed aft.
Never install AS888 at a level
lower than the inlet of the bilge
pump.