Nice IB Instrucciones Y Advertencias Para El Instalador página 4

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 34
3.2) "Double-leaf" type systems.
In automation systems for "double-leaf" doors or gates the photocells can be positioned as shown in figure 4 for gates or as shown in fig-
ure 5 for projecting up-and-over doors.
4
The figures show the maximum number of photocells possible, although a smaller number may be installed; during programming unit IB will
automatically recognise the devices that are effectively connected.
For unit IB to identify photocells connected to bluebus each must be assigned an address in accordance with its specific function in the sys-
tem. The addressing operation is performed by setting up the jumpers as specified in table 3 for each TX / RX pair.
Table 3
"Double-leaf" type systems
"External low-mounted" photocell on double-leaf system or
FOTO
"internal low-mounted" photocell on projecting up-and-over
door wit activation during closing.
"Outside high-mounted" photocell on two-leaf system or
FOTO II
"inside high-mounted" photocell on projecting up-and-over
door with activation during closing.
"Internal low-mounted" photocell on double-leaf system or
FOTO 1
"external low-mounted" photocell on projecting up-and-over
door with activation both during closing and during opening.
"Internal high-mounted" photocell on double-leaf system or
FOTO 1 II
"external high-mounted" photocell on projecting up-and-over
door with activation both during closing and during opening.
FOTO 2
"Right-hand" photocell with activation during opening.
FOTO 2 II
"Left-hand" photocell with activation during opening.
Note A: photocells FOTO, FOTO II change the status of the "foto" relay: when either of these two photocells is engaged unit IB will open
the contact of the "foto" output relay.
Note B: photocells FOTO 1 and FOTO 1 II change the status of the "foto 1" relay: when either of these two photocells is engaged unit IB
will open the contact of the "foto 1" relay.
Note C: photocells FOTO 2 and FOTO 2 II change the status of the "foto 2" relay: when either of these two photocells is engaged unit IB
will open the contact of the "foto 2" relay.
4
Photocell
5
Warning: during the opening and closing phases the door must
not engage photocells FOTO 1 and FOTO 1 II.
Jumpers
Activation on IB output
"foto" relay
(see note A)
"foto" relay
(see note A)
"foto 1" relay
(see note B)
"foto 1" relay
(see note B)
"foto 2" relay
(see note C)
"foto 2" relay
(see note C)
Tabla de contenido
loading

Tabla de contenido