Utilice El Comando Siguiente Para Ver El Estado De La Batería - Oracle SuperCluster T5-8 Guia Del Propietario

Tabla de contenido
disk controller cache might go into WriteThrough caching mode during the learn cycle. Disk write
throughput might be temporarily lower during this time. The message is informational only, no
action is required.
3.
Utilice el comando siguiente para ver el estado de la batería:
/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuStatus -a0
#
A continuación, se muestra un ejemplo de la salida del comando:
BBU status for Adapter: 0
 
BatteryType: iBBU08
Voltage: 3721 mV
Current: 541 mA
Temperature: 43 C
 
BBU Firmware Status:
 
Charging Status : Charging
Voltage : OK
Temperature : OK
Learn Cycle Requested : No
Learn Cycle Active : No
Learn Cycle Status : OK
Learn Cycle Timeout : No
I2c Errors Detected : No
Battery Pack Missing : No
Battery Replacement required : No
Remaining Capacity Low : Yes
Periodic Learn Required : No
Transparent Learn : No
 
Battery state:
 
GasGuageStatus:
Fully Discharged : No
Fully Charged : No
Discharging : No
Initialized : No
Remaining Time Alarm : Yes
Remaining Capacity Alarm: No
Discharge Terminated : No
Over Temperature : No
Charging Terminated : No
Over Charged : No
 
Relative State of Charge: 7 %
Charger System State: 1
Charger System Ctrl: 0
Charging current: 541 mA
Absolute State of Charge: 0%
 
Max Error: 0 %
Exit Code: 0x00