5. TROUBLESHOOTING

5.1

System cabling

Verify the power cable from the cutter unit is plugged
in and secured into the power supply or power adapter
cable (see A below).
Verify the power cable from the feed motor is plugged
in and secured into the connector located on the
bottom of the cutter unit (see B below).
Power Supply
Configuration
Verify the power supply is plugged into an appropriate
outlet socket (not applicable if using battery power
supply).
If not using a Rev 12/08 power supply (see C below),
verify power adapter cable (see D below) is properly
connected between the power supply and cutter unit
(see Section 9.3 "Replacing the AC power supply with
the battery pack" for proper installation).
1. Plug in and secure into power supply
2. Plug in and secure to cutter unit power cable
3. Plug in to power supply foot switch port
Verify power supply power switch is turned ON, cutter
unit green light is ON solid and red light is OFF.
FillPak
TT with Cut Mechanism Operator Manual - EN
®
Power Adapter Cable
Configuration
Verify the top cover is in place and snapped in position.
EN
8