Connection Plugs; Off/Run/Choke Switch; Rpm; Generator Status Lights - Powermate PM2000i Manual Del Propietário

Generador portatil
Ocultar thumbs Ver también para PM2000i:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Connection Plugs

120 VAC, Duplex Receptacle
The 120 Volt outlet is overload protected by
the 15 Amp push button circuit protector. See
Figure
2-3. Each receptacle will power 120
Volt AC, single phase, 60 Hz electrical loads
requiring up to 1700 watts (1.7 kW).
Figure 2-3. 120 VAC, Duplex Receptacle

Off/Run/Choke Switch

This controls the ON/OFF functions, choke
and fuel valve operation. See
• The OFF position (1) stops the engine and
shuts off fuel flow.
• The RUN position (2) is for normal opera-
tion and to gradually reduce the use of the
choke.
• The CHOKE position (3) switches the fuel
valve on to start the engine.
NOTE: The CHOKE is not required to start a
warm engine.
3
Figure 2-4. Dial (example)

RPM+

Optimizes engine RPM to reduce fuel con-
sumption and noise.
Owner's Manual for Portable Generator
000424
Figure
2-4.
2
1
002347

Generator Status Lights

See
Figure
2-5.
• Overload LED (orange): Indicates system
overload (2). During motor starting it is nor-
mal for the overload LED to illuminate for a
few seconds. If LED stays illuminated and
the ready LED turns off, the engine will con-
tinue to run without output power. Remove
all applied loads and determine if attached
devices
exceed
power. Check for faulty or shorted connec-
tions. To restore electrical output, turn dial
OFF to reset. Start engine. If condition was
corrected, the orange LED will not illumi-
nate and electrical output will be restored.
Loads can be applied once the green LED
illuminates. If the orange LED returns, con-
tact an IASD.
• Low Oil Level LED (red): Illuminates when
oil level is below safe operating level.
Engine shuts down (1).
• Power LED (green): Indicates output from
generator (3) (unless there is a low oil or
overload condition).
3
2
1
Figure 2-5. Status Indicators

Circuit Protectors

The AC receptacles are protected by an AC
circuit protector. If the generator is overloaded
or an external short circuit occurs, the circuit
protector will trip. If this occurs, disconnect all
electrical loads to determine the cause of the
problem before using the generator again.
Reduce the load if the circuit protector is
tripped.
NOTE: Continuous tripping of the circuit pro-
tector may cause damage to generator or
equipment.
Push the button of the protector to reset the
circuit protector.

Remove Contents from Carton

1. Open carton completely by cutting each
corner from top to bottom.
2. Remove and verify carton contents prior to
assembly. Carton contents should contain
the following:
recommended
output
010489
7