Parameter configuration SCE-020-03 with flow-turbines from
other suppliers:
1.
Setting the decimal place (watch the K-factor) according
to Section 4.2.1
2.
Setting the K-factor according to the given formula.
M3 is selected with the + / - keys and the parameter
selection is activated with SET . Then enter the K-factor
with the + / - keys and confirm with SET . The setting is
ended with SET .
Setting iPr = 0
3.
Select M4 with the + / - keys and activate the parameter
selection with SET . Then enter iPr = 0 with the + / - keys
and confirm with SET . The setting is ended with SET .
4.
Saving the configuration
The parameter configuration is ended as soon as the iPr
value is confirmed with SET . This configuration is saved
with End . A further confirmation with End saves the
parameter configuration. The instrument switches
automatically into the operating mode Measuring and
Display .