Combination With Sensocontrol Flow-Turbines - Parker SensoControl SCE-020 Instrucciones Para El Manejo

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 187
4.4.1 Combination with SensoControl flow-
turbines
Using a SensoControl flow-turbine (for example SCFT-300-11-07),
the following adjustments must be undertaken:
iPr
0
Determination of the k-factor FACt (M3)
The parameter FACt is a k-factor which is related to a frequency of
1000 Hz. For example:
FACt = [ K (1000) ].
This value is indicated on turbines belonging to the Parker
SensoControl program.
FACt
Example:
K (1000)
Accordingly, the value of the k-factor is 500.
Select M3 with the + / - keys and activate the parameter selection
with SET . Then enter the k-factor using the + / - keys and confirm
with SET . The configuration is ended with SET .
The parameter iPr must be set at 0 for this application!
Select M4 with the + / - keys and activate the parameter selection
with SET . Then enter iPr = 0 with the + / - keys and confirm with SET .
The setting is ended with SET .
The parameter configuration is ended as soon as the iPr value is
confirmed by pressing the SET key. This configuration is saved with
End . The parameter configuration is saved by a further confirmation
with the SET key. The instrument switches automatically into the
operating mode Measuring and Display .
FACt
K(1000)
Label SCFT
=
500 / 1000
- 19 -
Tabla de contenido
loading