2.2. Non-approved cleaning agents

∙ The use of flammable fluids is forbidden. The use of material with a flashpoint < 60°C, such as motor gasoline (petrol),
is forbidden.

2.3. Norms

EN
∙ Indispensably note the guideline for devices for cleaning workpieces with cleaning agents (amongst others the
DGUV-information 209-088, formerly BGR 180)! The same applies to the requirements of the Water Management Act
(German WHG), the ordinance on systems for handling water-polluting substances (German AwSV) as well as leaflet
M043 – Hydrocarbon based cleaner (formerly BGI 880).

3. OPERATING PRINCIPLE

3.1. How the machine works

A self-priming pump delivers the cleaning fluids from the tub to the cleaning brush (hollow brush) when the on / off mechanism on
the handle is pressed.
When the on / off mechanism is released, the flow of the cleaning fluid is immediately stopped.
Old goods will be collected by IBS Scherer and recycled as long as the mixing ban has been adhered to.
The IBS-Parts Cleaning Device Type A comprises:
1
Handle
2
Self-priming pump
3
Support
4
Brush pipe with cleaning brush
5
On / off mechanism
6
Tub
7
Castors with Eurostop
8
Rocker switch
9
Plug