Service interval reminder
DE
The Service interval reminder function is an aid to carry out a safety check on your boiler at
regular intervals. This function will be enabled and reset by a service professional.
EN
FR
Display shows alternating "SEr" and days until service is due on second line.
Then need to arrange boiler service
Whenever switching to and from Frost protection, the days until next service
IT
due will be shown.
NL
Display shows alternating "SEr...duE" indicates that the service day has
ES
expired.
Thermostat can still be fully operated but warning remains until boiler service
PT
is done.
CS
Display shows alternating "SEr...duE" and "OFF" indicates that the service
HU
day has expired and the thermostat is switched off.
The thermostat can only be operated in Comfort mode for 60 minutes
PL
whenever turning the knob or pressing the advance button.
SV
FI
ZH
TR
EL
RO
DA
A6V101035986_en--_c
2018-06-21
Parameter setting
Subject to alteration
Parameter setting mode
1.
Press RESET on the rear for 5 seconds until "P01" appears.
Note: Pressing the button longer than 10 seconds resets the
thermostat.
2.
Press advance button and the parameter value on second line flashes
and is ready for adjustment.
3.
Adjust the parameter using setting knob.
4.
Press advance button once to confirm the setting.
5.
Rotate the setting knob clockwise to next parameter and repeat steps
2 to 4.
6.
Exit the parameter setting mode by rotating the setting knob clockwise
to "End" and pressing advance button button once.
Parameters:
·
P01 Control behaviour: 2-position 1K / 2-position 0.5 K / PID fast /
PID slow (factory-setting)
·
P02 Maximum temperature range
·
P03 Minimum temperature range