G
B
Auxiliary light timeout
There is the possibility to set the delay of switching-off of the auxiliary light after the automation stops
Clock feature
Input OPEN becomes input clock in case it is possible to connect a timer for the programmed opening of the automation. The contact is understood as a command to opening and to stay open as
long as this status stays closed.
When the contact is opened, then the unit reset its normal operation, waiting for a command gived by the user (if the automatic closing is required, then it must be enabled from the menù).
Deceleration
It allows to select the deceleration ramp between the normal movement speed and the low speed.
1: slow deceleration ramp (By factory for SUPER 3000 FAST and JOLLY FAST)
10: Fast deceleration ramp
Encoder
If the motor is equipped with a suitable encoder, then it is possible to enable the featurealities of the encoder. In such way the control board does not work any longer "by time" but "with encoder"
instead. It is possible to detect the possible blocking of the motor.
Sensor level
If it is enabled, it allows to modify the intervention sensitivity of the "stop motor" sensor. Decrease the value that is set in order to have higher sensitivity. If the sensitivity is too high and the sensor
operates without any apparent reason, then increase the value.
Sensor inversion
Allows to define the reaction of the door in case the "stop motor" sensor applies. If the reversing is not activated, then the door stops and waits for a new command. If the reversing is activated,
then the door reverses shortly in case the sensor applies during the opening; it open completely in case the sensor applies during the closing phase of the door.
10. RESET of the control board (Menu C - Reset)
Reset of the unit according to the display indications; this reset the control board to its factory settings
WARNING: all programming and personal settings must be repeated after the reset of the control board!
11. BACKLIGHTING OF THE DISPLAY (Menu C - Display light)
Enter MENU C and follow the instructions shown on the display in order to enable/disable the backlighting of the display itself.
The control board operates the feature Energy saving which automatically switches off the display after the unit is inactive since some minutes.
The backlighting is automatically reactivated (if this feature is enabled) when the user operates on the control board.
12. ELECTROBRAKE or ELECTRIC LOCK output
The type of output depends on the setting of the parameter "Motor Brake" See table page 40.
Connection
to the board
ELECTROBRAKE
JOLLY
44