G
B
4.2 MENU A (key P1) - List of parameters
The following table lists the entries of menu A and reports a short description of the parameters that can be adjusted.
Refer to paragraph ADVANCED FEATURES for more details
MENU A
Photocell Invertion
Sensor Inversion
Timed closure of the door (only from total or pedestrian opening)
Auto Reclosing
OFF: disabled. (By factory for SUPER 3000 FAST and JOLLY FAST)
Timer
HH:MM:SS: time of persistence in opening position
Immediate closing after the intervention of the photocell (only from total or pedestrian opening)
Photocell
OFF: disabled. (By factory for SUPER 3000 FAST and JOLLY FAST)
Auto Reclose
ON: the door closes 3 s after the contact between photocell has restored
Motor Brake operation (for motors with high inertia).
OFF: disabled (Suggested for SUPER 3000 FAST)
1: electronic brake (Don't use with SUPER 3000 FAST !)
Motor Brake
2: activation of the contact for an external brake. Active with still motor
3: activation of the contact for an external brake. Active when motor is moving. (By factory for SUPER 3000 FAST and JOLLY FAST)
4: pre-activation of the contact for an external brake. Active with still motor
5: pre-activation of the contact for an external brake. Active when motor is moving
"Dead Man" mode. The motor moves only by means of a permanent command
Dead Man
OFF: disabled. (By factory for SUPER 3000 FAST and JOLLY FAST)
ON: enabled (WARNING: automatic motions are disabled)
Condominium feature. The commands S.S. and PED allow only the opening of the door
Condominium
OFF: disabled. (By factory for SUPER 3000 FAST and JOLLY FAST)
ON: enabled (WARNING: enable the "Automatic Re-Closure" in order to close)
Photocell intervention modality
OFF: the door stays still until the obstacle is removed, and then opens completely
ON: the door opens completely (this feature does not apply in opening). (By factory for SUPER 3000 FAST and JOLLY FAST)
Functional test of the photocell; it is executed before the door moves
Photo Test
OFF: disabled. (By factory for SUPER 3000 FAST and JOLLY FAST)
ON: test activated (WARNING: supply the photocell with power as shown in the scheme)
Modality of operation of the safety edge (sensible edge)
Edge Inversion
OFF: the door stops
ON: the door opens completely (this feature does not apply in opening). (By factory for SUPER 3000 FAST and JOLLY FAST)
Functional test of the safety edge; it is executed before the door moves
Edge Test
OFF: disabled. (By factory for SUPER 3000 FAST and JOLLY FAST)
ON: test activated (WARNING: supply the safety edge with power as specified in the chap. 2.12)
Short flash before the motion of the door
Pre-Blink
OFF: disabled. (By factory for SUPER 3000 FAST and JOLLY FAST)
ON: enabled
Modality of featureing of the auxiliary output for lighting
Area light
OFF: courtesy light. (By factory for SUPER 3000 FAST and JOLLY FAST)
ON: zone light (lit-off only when the door is completely closed)
Auxiliary light's switching-off delay for lighting
Aux Light Time
OFF: Auxiliary light's output disabled
HH:MM:SS: switching-off delay - auxiliary light's output enabled. (1 minute - By factory for SUPER 3000 FAST and JOLLY FAST)
Programmed opening feature
Clock
OFF: disabled. (By factory for SUPER 3000 FAST and JOLLY FAST)
ON: the door opens and stays open until the OPEN input is active
Select the deceleration ramp between the normal movement speed and the low speed.
Deceleration
1: slow deceleration ramp. (By factory for SUPER 3000 FAST and JOLLY FAST)
10: Fast deceleration ramp
Functioning with encoder (only for motors equipped with a suitable encoder)
Encoder
OFF: disabled. (By factory for SUPER 3000 FAST and JOLLY FAST)
ON: enabled (WARNING: the re-programming of the runs is needed)
Level of operation of the "motor still sensor" (with active encoder only)
Sensor level
OFF: sensor disabled. (By factory for SUPER 3000 FAST and JOLLY FAST)
NNN : sensor enabled - adjustment of operation's sensitivity
Modality of operation of the "motor still sensor" (with active encoder only)
OFF: the door stops
ON : reverses shortly in opening; opens completely in closing. (By factory for SUPER 3000 FAST and JOLLY FAST)
EXIT