Start-up
Pos: 122 /Alle Produkte/Dummy_module/Abstand 6 pt @ 7\mod_1196627997106_0.doc @ 41651 @
Pos: 123 /Alle Produkte/"Achtung"-Texte/SIC E-Achtung - Netzstecker ziehen @ 11\mod_1250680089636_121.doc @ 69898 @
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
− Prior to reaching into the water, disconnect the power supply to all units used in the water.
− Disconnect the power plug prior to carrying out work on the unit.
Pos: 124 /Alle Produkte/Dummy_module/Abstand 3pt @ 11\mod_1251901846864_0.doc @ 72826 @
Pos: 125 /Alle Produkte/"Achtung"-Texte/SIC Achtung - Nicht dimmen! @ 11\mod_1252588525329_121.doc @ 73510 @
Attention! Sensitive electrical components.
Possible consequence: The unit will be destroyed.
Protective measure: Do not connect the unit to a dimmable power supply.
Pos: 126 /Alle Produkte/Dummy_module/Abstand 3pt @ 11\mod_1251901846864_0.doc @ 72826 @
Pos: 127 /Alle Produkte/Inbetriebnahme/Inbetriebnahme - Netzstecker stecken/ziehen @ 11\mod_1251212083983_121.doc @ 70773 @
Switching on: Connect power plug to the socket. The unit switches on immediately when the power connection is
established.
Switching off: Disconnect the power plug.
Pos: 128 /Pumpen/Schlammsauger/Filtral 2500 UVC / 5000 UVC/Schauleuchte UVC @ 11\mod_1251275012506_121.doc @ 71033 @
The indicator lamp (Fig. D, 21) indicates the ON/OFF status of the UVC lamp.
Pos: 129 /Alle Produkte/Dummy_module/Abstand 6 pt @ 7\mod_1196627997106_0.doc @ 41651 @
Pos: 130 /Pumpen/Schlammsauger/PondoRell/Störung PondoRell 3000, 5000 @ 12\mod_1254388446496_121.doc @ 76653 @
Malfunctions
Malfunction
The unit is not operating
Delivery or fountain height insufficient or not
consistent,
Cloudy water
UVC lamp does not light up
Unit switches off after a short running period
Pos: 131 /Alle Produkte/Dummy_module/Abstand 6 pt @ 7\mod_1196627997106_0.doc @ 41651 @
Pos: 132 /Alle Produkte/Überschriften/H1 Reinigung und Wartung @ 7\mod_1196625212761_121.doc @ 41469 @
Maintenance and cleaning
Pos: 133 /Alle Produkte/Dummy_module/Abstand 3pt @ 11\mod_1251901846864_0.doc @ 72826 @
Pos: 134 /Alle Produkte/"Achtung"-Texte/SIC E-Achtung - Netzstecker ziehen @ 11\mod_1250680089636_121.doc @ 69898 @
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
− Prior to reaching into the water, disconnect the power supply to all units used in the water.
− Disconnect the power plug prior to carrying out work on the unit.
Pos: 135 /Alle Produkte/Dummy_module/Abstand 3pt @ 11\mod_1251901846864_0.doc @ 72826 @
Pos: 136 /Alle Produkte/"Achtung"-Texte/SIC Achtung - UVC @ 11\mod_1251210131939_121.doc @ 70745 @
Attention! Ultra-violet radiation.
Possible consequences: Eye or skin injury from burns.
Protective measures:
− Never operate the UVC lamp outside its housing.
− Never operate the UVC lamp in a housing that is defective.
Pos: 137 /Alle Produkte/Dummy_module/Abstand 3pt @ 11\mod_1251901846864_0.doc @ 72826 @
Pos: 138 /Pumpen/Schlammsauger/Filtral 2500 UVC / 5000 UVC/Gehäuse und Filtermedien reinigen Filtral 2500 UVC @ 11\mod_1251206135150_121.doc @ 70636 @
Filtral 2500: Opening the filter housing and cleaning the different filters (Fig. E-G)
Unscrew the branch valve (12) and the attachment elements. Pull the clamps on both sides of the bottom strainer
casing (2) to the side and lift off the top strainer casing (1). Remove the foam filter (3) and the UVC clarifying unit
including pump (20), and the fine foam filters (22), bio surface elements (23) and the gravel bag (24).
Clean the bottom strainer casing (2) and the top strainer casing (1) with clear water using a brush. Wash out foam
filters (3, 22), bio-surface elements (23) and the gravel bag (24) under running water. Do not use chemical cleaning
agents as they would kill the micro-organisms in the different filter media. At the beginning, this entails a reduced filter
capacity.
Pos: 139 /Alle Produkte/Dummy_module/===== Seitenwechsel ===== @ 0\mod_1125648978015_0.doc @ 1631 @
Cause
No mains voltage
Flow regulator excessively throttled
Nozzle blocked
Excessive pressure losses in the hoses
Intake openings blocked
Filters clogged
Rotor blocked
Pond extremely dirty
Quartz glass tube soiled
Lamp overheated. The temperature switch has
switched off the lamp
UVC lamp defective
UVC lamp is not correctly seated in the socket
Water temperature too high
Remedy
Check mains voltage
Set flow regulator
Unscrew and clean the nozzle insert
Reduce hose length and connecting parts to a
minimum, route hoses as straight as possible
Clean housing
Clean filters
Clean rotor
Remove algae and leaves from the pond,
change the water
Remove UVC clarifying unit and clean the
quartz glass tube
The lamp will automatically switch on again
once cooled down
Replace the UVC lamp
Correctly insert the UVC lamp into the socket
Note maximum water temperature of +35°