- GB -
Pos: 108 /Alle Produkte/Überschriften/H2 Sicherer Betrieb @ 7\mod_1204022429287_121.doc @ 44671 @
Safe operation
Pos: 109 /Alle Produkte/Sicherheit/Sicherer Betrieb/SIC ERW Sich. Betrieb - Keine Personen im Wasser @ 10\mod_1248351236831_121.doc @ 65210 @
− Only operate the unit if no persons are in the water!
Pos: 110 /Alle Produkte/Sicherheit/Sicherer Betrieb/SIC BAS Sich. Betrieb @ 11\mod_1250507406044_121.doc @ 69397 @
− Never operate the unit if either the electrical cables or the housing are defective!
− Do not carry or pull the unit by its electrical cable.
− Route all cables such that damage is excluded and nobody can trip over them.
− Never open the unit housing or its attendant components, unless this is explicitly required in the operating
instructions.
− Only use original spare parts and accessories for the unit.
− Never carry out technical modifications to the unit.
− Only have repairs carried out by customer service points authorised by OASE.
Pos: 111 /Alle Produkte/Dummy_module/Abstand 6 pt @ 7\mod_1196627997106_0.doc @ 41651 @
Pos: 112 /Alle Produkte/Überschriften/H1 Montage @ 7\mod_1202907725390_121.doc @ 43908 @
Installation
Pos: 113 /Alle Produkte/Dummy_module/Abstand 3pt @ 11\mod_1251901846864_0.doc @ 72826 @
Pos: 114 /Pumpen/Schlammsauger/Filtral 2500 UVC / 5000 UVC/Montage Filtral 2500 UVC @ 11\mod_1251204803439_121.doc @ 70553 @
Filtral 2500
Unit assembly (Fig. A)
Assemble the branch valve (12), the connection element for the ball joint (19), the nozzle tube (11) with the clamping
screw (10), nozzle mounting (9) and nozzle insert (8), then screw the assembly on the connection thread of the UVC
water housing (26) including the washer (14). The fountain height and shape depend on the nozzle insert (8) used.
If required, connect an additional hose for features or a water course to the lateral separately regulated connection of
the branch valve (12).
If you only use the lateral outlet at the branch valve (12), close the upper outlet using the cover cap (38).
Pos: 115 /Alle Produkte/Dummy_module/Abstand 3pt @ 11\mod_1251901846864_0.doc @ 72826 @
Pos: 116 /Pumpen/Schlammsauger/Filtral 2500 UVC / 5000 UVC/Montage Filtral 5000 UVC @ 11\mod_1251293290978_121.doc @ 71121 @
Filtral 5000:
Connecting the venting pump – option (Fig. V-Y)
If you wish to enrich the water with additional oxygen, connect the venting pump (Aqua Oxy) prior to installing the unit.
The Aqua Oxy scope of delivery includes the aeration stone and the hose.
Open the filter housing (Fig. V): Pull the clamps on both sides of the bottom strainer casing (2) to the side and lift off
the top strainer casing (1). Remove the foam filter (3).
Connect the aeration stone (figure W): Inside the housing, connect the aeration stone (25) with a section of the hose
(4) to the air connector (5) and place the aeration stone (25) between the gravel bags (24). Ensure that the hose is not
kinked. Connect the aeration pump (Aqua Oxy) to the air connector (5) outside of the housing. Read the aeration pump
documentation.
Close the filter housing (Fig. Y): Place the foam filter (3) in the bottom strainer casing (2). Attach the top strainer casing
(1) and press it onto the bottom strainer casing (2) until the clamps engage in the bottom strainer casing.
Important: Lead the connection cable (7) through the cable opening in the bottom strainer casing (2) and route the
cable such that pinching is avoided.
Unit assembly (Fig. A)
Assemble the reduction element (13), branch valve (12), nozzle tube (11) with the clamping screw (10), nozzle moun-
ting (9) and nozzle insert (8), then screw the assembly on the connection thread of the UVC water housing (26) inclu-
ding the washer (14). The fountain height and shape depend on the nozzle insert (8) used.
If required, connect an additional hose for features or a water course to the lateral separately regulated connection of
the branch valve (12). For this purpose, screw the reduction element (15) and the stepped hose adapter (16) on the
lateral outlet of the branch valve (12).
Pos: 117 /Alle Produkte/Dummy_module/Abstand 6 pt @ 7\mod_1196627997106_0.doc @ 41651 @
Pos: 118 /Alle Produkte/Überschriften/H1 Aufstellen @ 7\mod_1202907856718_121.doc @ 43934 @
Installation
Pos: 119 /Pumpen/Schlammsauger/Filtral 2500 UVC / 5000 UVC/Aufstellen / Düse einstellen @ 11\mod_1251292808663_121.doc @ 71093 @
Set-up the unit
Place the unit in the pond on a horizontal, firm and sludge free ground and ensure that it is completely covered by
water.
Setting the fountain/water feature (Fig. B, C)
Pull the nozzle tube (11) to the desired length. Undo the clamping screw (10), vertically align the nozzle tube (11) and
fasten the clamping screw (10) hand tight.
Fully open the rotary regulator (18) for the fountain. The rotary regulator (17) for the features or the water course is
also used to control the fountain/water feature. The additional water recirculation via the lateral outlet improves the
filtering effect, even if the feature or the water course is not connected.
Pos: 120 /Alle Produkte/Dummy_module/===== Seitenwechsel ===== @ 0\mod_1125648978015_0.doc @ 1631 @
14