Fitting The Uvc Clarifier; Connecting The Coarse Dirt Outlet; Connecting The Dirt Outlet - Oase Profi Clear Premium Compact L US Instrucciones De Uso

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

4.3.3

Fitting the UVC clarifier

The Bitron UVC clarifier is fitted to the filter container. This does not change the flow rate of the filter
system.
► It is necessary to remove a screen element to access the sealing plugs. (→ Removing/fitting a screen
element)
► For operation with two filter pumps, one filter pump is connected to the UVC clarifier, the other to the
inlet. (→ Connecting the inlet)
T I P
A non-return valve is installed in the connection for the filter pump to prevent water from returning. If a
filter pump each is to be connected to the Bitron and to the connection for the filter pump, the pump on
the connection for the filter pump can be switched on/off as required without any problems.
How to proceed:
 F
1. Undo the screws with a screwdriver and remove the sealing plugs.
2. Guide the outlet sockets of the Bitron with flat seals through the holes in the container wall.
3. Screw the adapters onto the outlet sockets and hand-tighten.
4. Screw the 30° inlet bends with cap nuts onto the adapters and hand-tighten.
– Position the inlet bends so that they are pointing downwards.
– Correctly positioned inlet bends prevent unintended overflow (emptying of the pond) and also serve
to reduce noise emissions.
5. Connect the Bitron to the filter pump in accordance with the operating manual.
4.3.4

Connecting the coarse dirt outlet

 G
The coarse dirt accumulated in the dirt channel drains away via the ∅ 4 in (DN 110) coarse dirt outlet (top
outlet on the container on the inlet side).
► A flexible coupling is more suitable than a PVC connection element for simple connection of the outlet.
► Connect a suitable ∅ 4 in (DN 110) pipe and drain the dirty water into the sewer system.
4.3.5

Connecting the dirt outlet

If necessary (cleaning, repair, winter storage), the water in the container can be drained via the ∅ 3 in
(DN 75) slide valve (at the bottom of the container).
► Connect a suitable ∅ 3 in (DN 75) pipe and drain the dirty water into the sewer system.
How to proceed:
 H
1. Remove the cap nuts and push the dirt outlet onto the connection.
2. Fit and tighten the cap nuts, tighten the hose clip.
3. Connect the pipe.
T I P
Bring together the ∅ 3 in (DN 75) pipe for the dirt outlet and the ∅ 4 in (DN 110) pipe for the coarse dirt
outlet and drain the dirty water into the sewer system through a joint ∅ 4 in (DN 110) pipe. This will
ensure that the dirty water pipe will be conveniently flushed out with sufficient pressure.
Questions, problems, missing parts?
Before returning to your retailer, call us at 1-866-627-3435, 8 a.m.-6 p.m., EST, Monday-Friday, or email
us at [email protected]. Or visit our website at www.oase-livingwater.com
- EN -
23
Tabla de contenido
loading

Tabla de contenido