6.5.2
EC: Extended cleaning time "Extra Cleaning"
To prevent larger deposits from building up in the dirt channel or pipework, the unit has an extended
cleaning time option. The extended cleaning time starts after a definable number of cleaning cycles. (→ In:
Time-dependent cleaning "Interval")
You can increase the cleaning time to flush out the pipe with additional water. The default setting for the
extended cleaning time is 20 s.
Proceed as follows
1.
Press
several times until EC appears in
the display.
2.
Press
for 5 s until the cleaning time is
indicated in the display.
3.
Press
several times to change the
value.
• To change the value quickly: Hold down the
button.
6.5.3
In: Time-dependent cleaning "Interval"
In addition to automatic cleaning, the unit can also perform a time-dependent cleaning cycle. This is
particularly useful for ponds containing fish. because even if there is only a small amount of dirt, excrement
is always removed from the water cycle before it leads to a build-up of nutrients.
Adjust the time interval to meet the requirements. The Drum Filter Module is normally optimally set with a
time interval of 20 minutes (default setting). The function is deactivated with a time setting of 0 minutes.
The time-dependent cleaning cycle does not have any influence on the automatic cleaning cycle that starts
when the water level is too low. After each automatic cleaning cycle, the time interval is reset and starts
again from the beginning.
Proceed as follows
1.
Press
several times until In appears in
the display.
2.
Press
for 5 s until the time is indicated in
the display.
3.
Press
several times to change the
value.
• To change the value quickly: Hold down the
button.
Questions, problems, missing parts?
Before returning to your retailer, call us at 1-866-627-3435, 8 a.m.-6 p.m., EST, Monday-Friday, or email
Information
To cancel and exit the menu: Either wait for 10 s or press
To cancel and exit the menu: Either wait for 5 s or press
• Adjustable range: 10 s – 9 min.
− A value in minutes is displayed with a line on the display (e.g. 6').
• Increment for 10 – 59 s: 1 s
• Increment for 1 – 9 min: 1 Min.
• The number can only be changed upwards. After the value 9 min, the
display
• returns to 10.
• Saving the set value: Wait for 5 s until the menu is automatically exited.
• Cancel without saving and exit the menu: Press
Information
• To cancel and exit the menu: Either wait for 10 s or press
• To cancel and exit the menu: Either wait for 5 s or press
• Adjustable range: 0.3 – 60 min
• 0 min: No time-dependent cleaning
• Increment: 1 min
• The number can only be changed upwards. Once the value 60 is reached,
the display returns to 0.
• Saving the set value: Wait for 5 s until the menu is automatically exited.