True RMS AC Flexible Clamp Meter 3000 A / English
6. Before each use, verify operation by testing a known working circuit that is within the
rating of this unit.
Steady red glow (not flash)indicates voltage present. If no indication, voltage could still
be present. Do not rely on this tester with shielded wire. Operation may be affected by
differences in socket design and type. If this product is used in a manner not specified by
the manufacturer, protection provided by the product may be affected.
4. SPECIFICTIONS & WORK DATA
Detection voltage range
100 V ac to 1000 V ac, 24 V ac to 1000 V ac
Power
3 V (AAA*2) alkaline battery
Operating temperature
–10°C to 50°C (14°F to 122°F)
Storage temperature
–10°C to 50°C (14°F to122°F)
Humidity
95% (0°C to 30°C (32°F to 86°F)
Altitude
3000 m
Contaminated distinction II
Weight
48.5 g
5. OPERATING INSTRUCTIONS
1. Checking for the presence of AC (100 V ac - 1000 V ac) voltage & radialisation.
Place the tip of the unit near an AC voltage and a steady glow display in the tip and a
continual beep
2. Checking for the presence of AC (24 V ac-1000 V ac) voltage & radialisation.
Press and hold the back black 24 button for 24 V test. Placing the tip of the unit
near an AC voltage and a steady glow display in the tip and a continual beep
3. Flashlight on & off.
Press and hold the back black button
for flashlight on. Release button for flashlight off.
6. BATTERY REPLACEMENT
a. Disconnect the unit from the circuit.
b. Remove the battery compartment.
c. Replace the batteries (observe polarity).
d. Slide back the battery compartment.
NOTE: If voltage test is not going to be used for a long time, please remove the battery.
2
Manuel d'instructions
RS VP-2
No d'inventaire: 161-1627
Testeur de tension
FR
02/01/2018 Version No. 001