AC voltage
Range
Resolution
400mV
4V
40V
400V
600V
Input impedance: 10MΩ.
Max. input voltage: 600V DC or AC rms.
Frequency response: 4V range: 40~400Hz; other ranges: 40Hz~1kHz sine
wave rms (avg. response)
hFE Transistor Gain
Range
hFE
Displays approx.
hFE transistoir gain
Resistance
Range
Resolution
400Ω
4kΩ
40kΩ
400kΩ
4MΩ
40MΩ
Open circuit voltage: approx. 0.5V
Overload Protection: 250V DC or AC rms.
Continuity
Function
The buzzer will sound if the measured resistance is less than
50Ω
Open circuit voltage: approx. 0.5V
Overload Protection: 250V DC or AC rms.
www.grupotemper.com
0.1mV
±(3.0% of reading + 3 digits)
1mV
10mV
±(0.8% of reading + 3 digits)
100mV
1V
±(1.2% of reading + 3 digits)
Description
Base current: approx. 10μA Vce:
(0-1000)
0.1Ω
1Ω
10Ω
±(1.2% of reading + 2 digits)
100Ω
1kΩ
10kΩ
±(2.0% of reading + 5 digits)
Description
KMD 04
Digital multimeter
Accuracy
approx. 2.8V
Accuracy
Instructions manual |
35