TECHNICAL DATA
Outdoor unit
SDH 17-060 MC2NO
SDH 17-085 MC4NO
Outdoor unit
SDH 17-060 MC2NO
SDH 17-085 MC4NO
Table 13.3 Capacity by combinations.

14 Additional datasheet

Outdoor unit
Indoor Unit 1
Indoor Unit 2
Indoor Unit 3
Indoor Unit 4
Outdoor
Sound Power Level
Outdoor
Sound Power Level
Indoor
Sound Power Level
Outdoor
Rated Airflow
Indoor
Rated Airflow
Indoor
Rated Airflow
Refrigerant type
GWP
Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less
to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.This appliance contains a refrigerant fluid with
a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global
GWP Fixed Text
warming would be 1975 times higher than 1 kg of C02, over a period of 100 years. Never try to interfere with the refrigerant circuit
yourself or disassemble the product yourself and always ask a professional.
Capacity control
Cooling function included
Heating function included
Average climate included
EN
Cold season included
Warm season included
Energy label
Pdesign
Cooling
SEER
Annual energy consumption
Energy label
Pdesign
Heating
(Average
SCOP
climate)
Annual energy consumption
Required back up heating cap at design conditions
A Condition (35°C - 27/19)
B Condition (30°C - 27/19)
Cooling
C Condition (25°C - 27/19)
D Condition (20°C - 27/19)
- 24 -
Combination of indoor units
Unit 1 Unit 2 Unit 3 Unit 4
25
25
25
35
25
25
35
25
25
25
35
Combination of indoor units
Unit 1 Unit 2 Unit 3 Unit 4
25
25
25
35
25
25
35
25
25
25
35
Cooling
Nom.
Heating outdoor 7(6) / indoor 20 (max 15) dB(A)
Cooling
Nom.
Cooling
Heating
Cooling
Heating
Pdc
EERd
Pdc
EERd
Pdc
EERd
Pdc
EERd
Design load
Seasonal efficiency
Pdesignh
SCOP/W
/
/
/
/
/
/
/
/
Design load
Seasonal efficiency
Pdesignh
SCOP/C
/
/
/
/
/
/
/
/
SDH 17-050 MC2NO* SDH 17-085 MC3NO* SDH 17-085 MC4NO
SDH 17-025 NMWI
SDH 17-025 NMWI
/
/
dB(A)
63
N.A. **
53
dB(A)
m³/min
3200
m³/min
3200
m³/min
500
m³/min
500
R410A
1975
Variable
YES
YES
YES
NO
NO
YES
kW
5,00
5,60
kWh
313
YES
kW
4,60
3,80
kWh
1695
kW
1,5
kW
5,139
3,410
kW
3,695
4,870
kW
2,159
7,340
kW
2,030
10,860
Heating/Warmer
Annual electricity
consumption
QHE
/
/
/
/
Heating/Colder
Annual electricity
consumption
QHE
/
/
/
/
SDH 17-020 NMWI*
SDH 17-025 NMWI
SDH 17-035 NMWI
/
68
N.A. **
51/53/57
3800
3800
450/500/550
450/500/550
R410A
1975
Variable
YES
YES
YES
NO
NO
YES
8,00
5,10
549
YES
7,00
3,80
2579
1,600
7,568
2,901
5,308
4,603
3,588
6,557
3,371
8,764
SDH17-MNW-I_EN - 11/14 - Saunier Duval
Energy efficiency
class
/
/
/
/
Energy efficiency
class
/
/
/
/
SDH 17-020 NMWI*
SDH 17-020 NMWI*
SDH 17-020 NMWI*
SDH 17-020 NMWI*
68
N.A. **
51
4000
4000
500
500
R410A
1975
Variable
YES
YES
YES
NO
NO
YES
8,00
5,10
549
YES
7,00
3,80
2579
1,600
7,598
2,950
5,671
4,160
3,497
5,890
3,150
8,630