English
16
5 Rinse the brew group thoroughly with lukewarm water. Clean the upper
filter carefully.
6 Let the brew group air-dry.
Note: Do not dry the brew group with a cloth to prevent fibers from
collecting inside the brew group.
Cleaning the brew group with coffee oil remover tablets
Caution: Only use coffee oil remover tablets for cleaning. They do not
have a descaling function.
1 Place a container under the coffee dispensing spout.
2 Press the AROMA STRENGTH button and select pre-ground coffee.
3 Put a coffee oil remover tablet in the pre-ground coffee compartment.
4 Press the ESPRESSO LUNGO button. The machine dispenses water from
the coffee dispensing spout.
5 When the progress bar has reached the middle, set the main switch on
the back of the machine to OFF.
6 Let the coffee oil remover solution act for approximately 15 minutes.
7 Set the main switch to ON. Press the standby button.
8 Wait until the machine performs an automatic rinsing cycle.
9 Perform the 'Weekly cleaning of the brew group' procedure.
10 Remove the drip tray with the coffee grounds container. Empty the drip
tray and the coffee grounds container and place them back in the
machine.
11 Press the AROMA STRENGTH button and select pre-ground coffee.
12 Press the ESPRESSO LUNGO button. The machine dispenses water from
the coffee dispensing spout.
13 Repeat steps 12 and 13 twice. Discard the dispensed water.
Reinserting the brew group
1 Before you slide the brew group back into the machine, make sure the
two yellow reference signs on the side match. If they do not match,
perform the following step:
-
Make sure the lever is in contact with the base of the brew group.
2 Make sure that the yellow locking hook of the brew group is in the correct
position.