Commissioning; Alignment - SICK WSU26-2 Instrucciones De Servicio

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 59
Chapter 6
6

Commissioning

8 008 631/P134/20-12-04 © SICK AG • Safety Systems • Germany • All rights reserved
160
Commissioning
The device is switched on by connecting the supply voltage to
the sender unit and to the receiver unit. The device is ready for
operation after approx. 2 s.
For more detailed information on this, see Technical Descripti-
on WSU/WEU 26/2.
6.1
Alignment using the indicator lights
Switch on the supply. The yellow LED on the WSU should light
up.
Align the modules with each other such that the green and yel-
low LEDs on the WEU light up.
WSU
yellow
For optimum alignment, determine the limits of the transmissi-
on and receiving range by pivoting the sender and receiver
units horizontally and vertically. When the device leaves its re-
spective optical range, the yellow LED on the WEU begins to
flash. Then fix the sender and receiver units in the middle of
the determined optical range.
Operating Instructions
WSU/WEU 26/2
WEU
green
yellow
red
Tabla de contenido
loading

Este manual también es adecuado para:

Weu26-2