11. USE AND PRÉCAUTIONS
The compact macerator is used like a conventional toilet and requires minimal maintenance (see
14. Maintenance ).
Warning: the quality of the rinsing of the bowl depends on the water pressure.
For optimum rinsing, the outlet pressure of your tap must be at least 1.7 bar
dynamic (and maximum 10 bar).
Advice: in the regions where the water of the network is dirty or sandy, we recommend inserting
an additional filter between the stop valve and the device, in order to prevent complicated mainte-
nance work should be solenoid valve become clogged.
12. DUAL-FLUSH OPERATION
Sanicompact
Comfort + is controlled by an electronic programmer. The operating life varies
®
according to the cycle chosen:
- Eco cycle (light grey button)
- Normal cycle (dark grey button)
Normal cycle
If necessary, you have the option of extending the rinsing duration if the default setting is not suffi-
cient (low supply pressure).
To change the program:
• Model without handbasin option: press the 2 grey buttons simultaneously and for 5 seconds.
Model with handbasin option: press the dark grey button for 5 seconds.
The motor starts up for 2 seconds, which means you are now in programming mode.
• Each time you press the dark grey button, you increase the duration of the rinse cycle by one
second: each pulse is confirmed by the motor starting up briefly.
• Each time you press the light grey button, you decrease the duration of the rinse cycle by one
second: each pulse is confirmed by the motor starting up briefly.
• To exit the programming mode: don't do anything for several seconds. The motor starts up for 2
seconds, which means you have exited programming mode.
Comment: the modified cycle remains in the memory even after a power failure.
The device must not be used to remove foreign bodies such as periodical swabs,
condoms, rags, cotton, solvents, oil, etc. that could damage the device.
Such use will invalidate the warranty.
NEVER USE THE DEVICE IN THE EVENT OF A POWER FAILURE!
In case of excessive use, the device is protected by a thermal probe.
Do not use for commercial or industrial applications.