Operating Elements - Metabo WIG 170 AC/DC Manual De Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
ENGLISH
2-step mode with HF-igni-
tion
4-step mode with HF-igni-
tion
Stick elevtrode welding and
Arc-Force function
Gas postflow time
Downslope time
Balance
Reduced cleaning action
Increased cleaning action
Mains voltage
S-Test
Excess temperature
Connector for remote con-
trol unit
Connector for TIG torch
Connector for TIG torch gas
hose
Connector for gas supply
Main switch
Information on the name plate:
1
2
3
8
10
All manuals and user guides at all-guides.com
1
Manufacturer
2
Machine designation
3
Serial number
4
Standard information – This
machine meets the requirements
of the standards mentioned
5
CE mark – This machine con-
forms to EC directives as per
declaration of conformity
6
Waste disposal symbol – the
machine can be disposed of
through the manufacturer
7
Electrical performance data
8
Date of manufacture

3. Operating Elements

14
9
Carrying strap/shoulder strap
4
5
Adjustable in length for carrying
− by hand (shown in illustra-
− on the shoulder.
10
Connector for remote control
unit
11
Connector for torch gas hose
12
Connector for TIG torch
pilot lead
13
Welding current connector
(+ pole)
6
7
14
Welding current connector
(- pole)
9
10
11
12
13
tion)
15 16 17
18 19 20
21 22 23
28
27
26
15
Welding current control
16
LED display
Displays the currently set weld-
ing current.
17
I1 welding current indicator
− LED illuminated:
welding current active.
18
I2 secondary current indicator
(4-step mode only)
− LED illuminated:
secondary current I2 is
active.
19
I2 secondary current control
20
Downslope time control
21
Equipment-on indicator
− LED illuminated:
Machine is turned on, no
faults detected.
− LED off:
Machine turned off or fault
present.
22
Excess temperature indicator
− LED illuminated:
Excess temperature fuse
tripped and control disa-
bled.
23
Gas postflow time control
24
S-Test indicator
− LED illuminated:
Machine ready to operate.
− LED off:
S-Test triggered, machine
not ready to operate.
25
Current type selector
26
Balance control
27
Frequency control
28
Operating mode selector
25
24