FUNCTIONING OF THE APPARATUS
Depending on the model, the unit is equipped with the following controls:
DHG556XP, DHG576XP, DHG577XP
CONTROLS - Fig. 9:
A) ON/OFF - lamps. This button is also used for the alarm function of the grease and charcoal filters.
Filter alarm: After 30h of motor operation, the L1 LED comes ON and remains ON (the grease filters have to be cleaned). After
120h of motor operation, the L1 LED comes ON and flashes (the charcoal filter have to be changed if the hood is so equipped).
The Filter Alarm is ONLY given with the motor is OFF. The Filter Alarm is cancelled (HOUR meter reset) by holding down button
A for 2". B) Press button B to start the motor at Speed 1. The speed is shown by the L2 LED coming ON. When held down
for 2", the motor switches off. A single pressure on the button when the LED is ON activates the timer function (motor ON for
5'), shown by the flashing LED. To cancel the timer function, press the button again ONCE. C) Press button C to start the motor
at Speed 2. The speed is shown by the L3 LED coming ON. A single pressure on the button when the led is on activates the
timer function (motor on for 5'), shown by the flashing led. To cancel the timer function, press the button again ONCE. D) Press
button D to start the motor at Speed 3. The speed is shown by the L4 LED coming ON. A single pressure on the button when
the led is on activates the timer function (motor on for 5'), shown by the flashing led. To cancel the timer function, press the
button again ONCE. E) Press button E to start the il motor at Speed 4 (B = Booster). The speed is shown by the L5 LED coming
ON. A single pressure on the button when the led is on activates the timer function (motor on for 5'), shown by the flashing led.
To cancel the timer function, press the button again ONCE.
ATTENTION : BY ACTIVATING THE TIMER FUNCTION, THE MOTOR SWITCHES OFF AFTER 5 MINUTES.
ATTENTION : WHEN THE LED L1 LIGHTS UP IT IS TIME TO CLEAN THE GREASE FILTERS OR REPLACE THE
CHARCOAL FILTER.
DHG589XP
CONTROLS - Fig. 10:
A) ON/OFF - lamps. This button is also used for the alarm function of the grease and charcoal filters.
Filter alarm: After 30h of motor operation, the L1 LED comes ON and remains ON for 30" (the grease filters have to be cleaned).
After 120h of motor operation, the L1 LED comes ON and flashes for 30" (the charcoal filter have to be changed if the hood
is so equipped). The Filter Alarm is ONLY given with the motor is OFF. The Filter Alarm is cancelled (HOUR meter reset) by
holding down button A for 2".
B) The button B activates/deactivate sensor function (when activated the sensor is lit by the LED L2).
C) Press button C to start the motor at Speed 1. The speed is shown by the L3 LED coming ON. When held down for 2", the
motor switches off.
D) Press button D to start the motor at Speed 2. The speed is shown by the L4 LED coming ON.
E) Press button E to start the motor at Speed 3. The speed is shown by the L5 LED coming ON.
F) Press button F to start the il motor at Speed 4 (B = Booster). The speed is shown by the L6 LED coming ON.
SENSOR SENSITIVITY: sensitivity of the sensor may be modified in accordance with individual requirements. Modify the
sensitivity by pressing simultaneously on the A and B buttons. The set sensitivity level will be displayed via the 4 flashing Leds
- L3, L4, L5, and L6. The desired sensitivity is set via the C, D, E, and F buttons (C being minimum, F being maximum). Set
the sensitivity level to minimum for gas cook tops, medium for glass-ceramic cook tops and maximum for induction cook tops.
WARNING: WHEN LED L1 LIGHTS UP, THIS INDICATES THAT THE GREASE OR CHARCOAL FILTERS REQUIRE
CLEANING.
FILTER SENSOR (activated via the B button): this device is equipped with a completely automatic system (Advanced Sensor
Control) for management of all hood functions. Thanks to the Advanced sensor Control (ASC), air circulating in the kitchen is
maintained clean and odour-free without requiring any user intervention. The sophisticated sensors are able to capture any type
of odour, vapour, smoke or heat caused by cooking. The ASC also captures any possible irregular gases present in the
environment.
When the sensor function is activated, the C, D, E and F buttons activate the speed temporarily, to then be overridden by the
automatic speed setting.
Fig. 10
Fig. 9
The 4th speed (B = Booster - intensive) is automatically lowered to 3rd speed after 5 minutes of operation to optimise energy
consumption.
- If the hood is left on (lights and/or motor), after 10 hours in the absence of commands from the user, it will automatically switch
to OFF condition with all services switched off.
- The Buzzer emits a "beep" each time that a command is set from the keyboard or remote control (optional).
- In the event of interruption of power during the hood, if you restore the hood in the OFF state, then the engine must be reactivate
manually.