9. Specifications
Model
S3M10K1B
OVERVIEW
Capacity
10 kVA/10 kW
Topology
INPUT
Voltage and Phase
Voltage Range
Frequency (Range)
Power Factor
Dual AC Input
Harmonic Distortion
OUTPUT
Voltage and Phase
AC Voltage Regulation
Power Factor
Frequency
Frequency Regulation
Overload (AC Mode)
Crest Factor
Harmonic Distortion
Waveform
Transfer Time
Parallel Capability
BYPASS
Bypass Voltage Range
Bypass Frequency Range
EFFICIENCY
AC Line Mode
ECO Mode
BATTERY AND CHARGER
Battery Type
DC Acceptance Voltage
Battery Configuration
Internal Only
Internal Battery Quantity
20 x 9 Ah
Runtime (100% Load) (est.)
4 min.
Runtime (50% Load) (est.)
10 min.
External Battery Packs (BP) /
Cabinet for UPS Models
without Internal Batteries
Recharge Time to 90%
≤ 8 hr.
Charging Current (Default)
1 – 20A (1.35A) 1 – 20A (2.7A) 1 – 20A (4.05A) 1 – 20A (2.7A) 1 – 20A (2.7A) 1 – 20A (4.05A) 1 – 20A (2.7A) 1 – 20A (4.05A) 1 – 20A (2.7A)
ENVIRONMENT
Operating Temperature
Storage Temperature
Operating Humidity
Operating Altitude
Audible Noise at 1 m
< 58 dBA
Heat Dissipation
(100% Load)
MANAGEMENT
Control Panel
Communications
SNMP Network Management Card (WEBCARDLX)**, Relay I/O Card Slot, EPO/REPO, Temp Probe, MODBUS RTU via RS-485, RS-232 and USB Ports
STANDARDS
Safety
EMC/EMI
Additional
PHYSICAL
Unit Dimensions
(H x W x D)
136 kg
Unit Weight
(300 lb.)
* Runtimes depend on the external battery cabinet model being used. ** Tripp Lite's WEBCARDLX is an optional accessory available for all models.
S3M10K2B
S3M10K3B
10 kVA/10 kW
10 kVA/10 kW
True On-Line Double Conversion; Voltage- and Frequency-Independent (VFI)
Ph-Ph 208/220V (Ph-N 120V/127V); 3-Phase, Neutral and Ground
-20%, +25% (Ph-Ph 166–260V or 176–275V) at 100% Load; -40%, +25% (Ph-Ph 125–260V or 132–275V) at <50% Load
Ph-Ph 208/220V (Ph-N 120V/127V); 3-Phase, Neutral and Ground
±1% of Nominal (Double-Conversion Mode, Converter Mode or Battery Mode); ±10% of Nominal (ECO Mode)
Selectable ±1%, ±2%, ±4%, ±5%, ±10% of Input (Default: ±10%)
Load ≤ 110%=1 hour; Load ≤ 125%=10 min.; Load ≤ 150%=1 min.; Load >150%=Bypass
≤ 1% THD (100% Linear Load); ≤ 3% THD (100% Non-Linear Load)
Parallel Up to 4 Units for Increased Capacity or N+N Redundancy
Upper Limit: +10%, +15%, +20% or +25% (Default: +20%); Lower Limit: -10%, -20%, -30% or -40% (Default: -30%)
12V Maintenance-Free Non-Spillable VRLA AGM/GEL
Internal Only
Internal Only
40 x 9 Ah
60 x 9 Ah
9 min.
20 min.
22 min.
45 min.
Refer to section 3.9.1 UPS and Battery Cabinet Compatibility
≤ 8 hr.
≤ 8 hr.
0 – 35˚ C (UPS with batteries.); -15 – 60˚ C (UPS without batteries.)
< 1000 m (Derate output power by 1% per 100 m above 1000 m.)
< 58 dBA
< 58 dBA
2457 BTU/h
Large 12.7 cm (5-inch) Multi-Language Touchscreen Display with Supplemental LEDs
UL1778:2014 (5th Edition); CAN/CSA-C22.2 No. 107.3-14 (3rd Edition)
ENERGY STAR 2.0, RETIE, IP20 Ingress Protection Rating; RoHS; ISTA 3B/Vibration, Shock and Tip tested.
187 kg
237 kg
(412 lb.)
(522 lb.
S3M10K-NIB
S3M15K2B
S3M15K3B
10 kVA/10 kW
15 kVA/15 kW
15 kVA/15 kW
50/60 Hz, Selectable (40 – 70 Hz)
≥ 0.99 (Linear Load)
Yes
< 2% THDi (100% Load)
1.0 (Unity Output Power Factor)
±0.1 Hz (Converter Mode or Battery Mode)
3:1 Maximum
Pure Sine Wave
0 ms (Line ‹–› Battery and Inverter ‹–› Bypass)
±10% (Adjustable)
Up to 94%
Up to 98%
±120V DC (240V DC) (Nominal)
External Only*
Internal Only
Internal Only
None*
40 x 9 Ah
60 x 9 Ah
27 – 88 min.*
6 min.
60 – 212 min.*
13 min.
Varies with BP
≤ 8 hr.
0 – 40˚ C (≤ 25˚ C for optimal battery lifespan.)
0 – 95% (Non-Condensing)
< 58 dBA
< 58 dBA
< 58 dBA
3686 BTU/h
FCC Part 15B Class A
868 x 250 x 900 mm
(34.2 x 9.8 x 35.4 in.)
81 kg
188 kg
(179 lb.)
(414 lb.)
(525 lb.)
71
S3M15K-NIB
S3M20K3B
15 kVA/15 kW
20 kVA/20 kW
External Only*
Internal Only
None*
60 x 9 Ah
13 min.
15 – 55 min.*
7 min.
27 min.
35 – 125 min.*
16 min.
≤ 8 hr.
Varies with BP
≤ 8 hr.
< 58 dBA
< 60 dBA
238 kg
82 kg
239 kg
(181 lb.)
(527 lb.)
S3M20K-NIB
20 kVA/20 kW
External Only*
None*
10 – 38 min.*
27 – 88 min.*
Varies with BP
< 60 dBA
4915 BTU/h
83 kg
(183 lb.)