Standard non-concealed installation

9.1.1 Removing the cover

f Open the water heater by undoing the screw and lifting the
cover up from the bottom.
9.1.2 Preparing the power cable
A
f Prepare the power cable.
Position for non-concealed
installation
Bottom, center
Bottom, left side of water heater
Bottom, right side of water heater ½˝ (20
Top, right side of water heater
Position for concealed instal-
lation
Bottom
Top
9.1.3 Preparation
f Cut a hole in the cable grommet to fit the selected connecting
cable. Fit the cable grommet.
9.1.4 Mounting the water heater
f Mark the 4 drill holes, referencing their position on the water
heater rear cover.
f Drill the holes and secure the water heater using suitable
fixing materials (screws and wall anchors are not part of the
standard delivery): Countersunk screw, Ø 4.5 mm, max. di-
ameter of screw-head 9 mm.
10
| DCE Plus
B
Dimension a
Dimension B
1½˝ (30
)
43/4˝ (120
)
mm
mm
½˝ (20
)
3½˝ (90
)
mm
mm
)
3½˝ (90
)
mm
mm
½˝ (20
)
3
/
˝ (80
)
1
mm
mm
8
Dimension a
Dimension B
½˝ (20
)
3½˝ (90
)
mm
mm
½˝ (20
)
3
1
/
˝ (80
)
mm
mm
8
f Connect braided steel flex connectors (recommended,
not supplied) or other pipework to the twin ½˝ NPT male
connectors.
f Open the shut-off valve in the cold water inlet line.
9.2

Electrical connection

WARNING Electrocution
Before beginning any work on the electric instal-
lation, be sure that main breaker panel switches
are "Off" to avoid any danger of electric shock. All
mounting and plumbing must be completed before
proceeding with electrical hook-up. Where required
by local, state or national electrical codes the circuits
should be equipped with a "ground fault interrupter".
The unit must be properly grounded in accordance
with state and local codes, or in absence of such
codes, in accordance with national electric code or the
Canadian electric code. Failure to electrically ground
the product could result in serious personal injury or
death.
WARNING Electrocution
The connection to the power supply is only permissible
as a permanent connection in conjunction with the re-
movable cable grommet. Ensure the water heater can
be separated from the power supply by an isolator that
disconnects all poles with at least 1/8˝ (3 mm) contact
separation.
CAUTION: DO NOT INSTALL IN A BATH ENCLOSURE OR
!
SHOWER STALL OR CONNECT TO A SALT-REGENERATED
WATER SOFTENER OR A WATER SUPPLY OF SALT
WATER
FOR USE ON AN INDIVIDUAL BRANCH CIRCUIT ONLY
CAUTION: CONNECT ONLY TO A CIRCUIT PROTECTED
BY A CLASS A GROUND FAULT CIRCUIT INTERRUPTER
USE COPPER CONDUCTORS ONLY
USE BONDING CONDUCTOR IN ACCORDANCE WITH THE
CANADIAN ELECTRICAL CODE, PART I
Supply this appliance only from a grounded system. A
!
green terminal (or a wire connector marked "G", "GR",
"GROUND", OR "GROUNDING") is provided for wiring
the appliance. To reduce the risk of electric shock,
connect this terminal or connector to the grounding
terminal of the electric service or supply panel with a
continuous copper wire in accordance with the electri-
cal installation code.
Material losses
!
Observe the type plate. The specified rated voltage must
match the supply line voltage.
Material losses
!
The DCE 13 Plus must only be connected to a 208 V or
220 V electrical supply. Connecting the DCE 13 Plus to a
240 V electrical supply will permanently damage the unit
and void the factory warranty.