iNSTallaTiON

alternative installation methods
f Seal the factory-fitted cable grommet with the plug included
in the standard delivery.

12.2 Electrical connection with short power cable

If the power cable is not quite long enough, you can install the
wiring block closer to the aperture in the water heater.
1 Cable grommet
f Reposition the wiring block from the top to the bottom. To do
so, unclip the wiring block by pushing it firmly to the left and
pulling it forwards. Clip the wiring block in at the bottom by
pushing it inwards and to the left until it clicks into place.
12.3 Concealed installation, electrical connection
from above
1 Cable grommet
2 Cable routing
f Break out the required aperture in the back panel for the
power cable (for positions, see section 16.1, "Dimensions and
connections", pg. 17). De-burr any sharp edges with a file.
f Cut a hole in the cable grommet to fit the selected connecting
cable. Fit the cable grommet.
f Reposition the wiring block from the bottom to the top. To do
so, unclip the wiring block by pushing it firmly to the left and
pulling it forwards. Turn the wiring block with connecting ca-
bles 180° clockwise. Lay the internal wiring under the cable
guide. Clip the wiring block in by pushing it inwards and to
the left until it clicks into place.
f Install the water heater and connect the power cable to the
wiring block as described in section 9.1, "Standard non-con-
cealed installation", pg. 10.
f Seal the factory-fitted cable grommet with the plug included
in the standard delivery.
www.stiebeleltronamericas.com
12.4 Electrical connection from the side, non-
concealed installation
f Cut and break out the required aperture in the water heater
back panel and water heater cover for the power cable (for
positions, see section 16.1, "Dimensions and connections",
pg. 17). De-burr any sharp edges with a file.
f Install the water heater and connect the power cable to the
wiring block as described in section 9.1, "Standard non-con-
cealed installation", pg. 10.
f Seal the factory-fitted cable grommet with the plug included
in the standard delivery.

12.5 Concealed installation, water connections

You will need the appropriate accessories to carry out the instal-
lation. See section 7.2, "Accessories", pg. 8. The installation
kit for concealed water connections (not supplied, part number
200017 – IW-Kit LA) contains:
1
- 2 x plugs to seal the apertures in the water heater back panel
- 2 x 45° twin connectors
- Filter screen with sealed edge for installation on the 45° twin
connector
- Flat gasket
Preparation
f Unscrew the twin connectors (including the filter screen) at-
tached to the water heater from the water supply pipes and
set them aside (not needed for this installation).
1
2
f Seal the 45° twin connectors from the concealed water con-
nection installation kit. Screw the 45° twin connectors into
the wall connector.