MODULE CONFIGURATION TABLE
IMPOrTaNT:
Before starting any configuration, press briefly 23 times to unlock the module. The module will lock again
automatically after 6 hours. It can also be locked immediately with 21 short presses.
Presses* Time
11
2 minutes
12
4 minutes
13
8 minutes
14
15 minutes
15
30 minutes
16
60 minutes (1 hour)
17
120 minutes (2 hours)
18
240 minutes (4 hours)
19
unlimited
* The flashes are visible on the Stop LED
located on the lower part of the frontal panel
DIRECT CONNECTION BETWEEN A YOKIS TRANSMITTER AND AN MFP6ARP
It is essential to involve the transmitter to the module to control a MFP6ARP via a transmitter.
Press the pushbutton to be connected on the transmitter (E), 5 times*.
The transmitter LED will start flashing for 30 seconds, indicating that the system is waiting for
connection.
* Each press must last less than 0.7 seconds
When the LED of the transmitter blinks, briefly press the "Connect" button of the MFP6ARP (on the front
of the module).
The transmitter LED will stop flashing.
Warning: the receiver must be powered.
The Led will light up on transmitters only if radio transmission was successful.
TRANSMITTER CONFIGURATION
The associated button will work according to the previously configured methods: Cycle (6 or 4 commands) or
Comfort/Eco, with or without timer.
The button can be reconfigured to ensure that pressing it forces the module in Eco mode.
To do this, press the button 10 time quickly and, when the LED flashes, press 4 times.
To return the button standard mode, press it 10 times and then 1 time.
The button can be reconfigured to ensure that pressing it forces the module in Comfort mode.
To do this, press the button 10 time quickly and, when the LED flashes, press 3 times.
To return the button standard mode, press it 10 times and then 1 time.
DS1054-050B
Presses* Functions
Reply
1 flash
2 flashes
20
Cycle mode (default) or Comfort/Eco toggle mode
3 flashes
21
Configuration lock
4 flashes
23
Configuration unlock
5 flashes
24
Cycle of 6 (default) or 4 commands
6 flashes
28
Restore current state in case of mains power blackout
7 flashes
(active by default)
8 flashes
29
Standard Features (default) or wireless pilot wire
9 flashes
30
Full reset to factory settings
31
State light feedback: On/Off (active by default)
P11
P2
Response on
LED of the module
10 flashes
1 flash
3 flashes
4 flashes
8 flashes
9 flashes
4 flashes
1 flash
Tabla de contenido
loading

Este manual también es adecuado para:

5454498

Tabla de contenido