3 - PROGRAM LEVEL #2
2.7A
TIME AUXILIARY OUTPUT (Y)
2.7.B only viewed if 2.7.A (y) is activated.
&
2.AB
Press the button
displays. The first display is used to set the turn on time of the output. The second one is used to set
the turn off on time of the output. An OFF setting cancels this option. With a set off time of "S" will turn
the output off at the back of service. All settings are in minutes. The setting time of the output has not
to be longer than the total time of regeneration.
Note: all setting times of the output are synchronised with regeneration cycle timing.
Ex.: - Turn on output at start of regeneration cycle 1, turn off after 10 min
- Start time display
- Stop time display
- Option cancelled
2.8A
TIME AUXILIARY OUTPUT (
Not viewed if; 2.8.b only viewed if 2.8.a is activated.
&
2.8B
Press the button
two displays. The first display is used to set the turn on time of the output. The second one is used
to set the turn off time of the output. An OFF setting cancels this option. With a set off time of "S"
will turn the output off at the start of service. All settings are in minutes. The turn on time of "r"
cannot be lower than the turn off time of "y".
Note: all setting times of the output are synchronised with regeneration cycle timing.
Ex.: - Turn on the output 15 min after the start of the regeneration cycle 1
- Turn off when in service
- Option cancelled
2.9A
CHEMICAL PUMP OUTPUT (
Not viewed in timeclock regeneration mode.
&
2.9B
Press the button
displays. This first display is used to set the turn on time (in minutes) of the output. This second
one is used to set the volume of water flow at which the output will turn on. The unit of measure
used in the second display depends on the display format chosen
Ex.: - Turn on the output for 1min after every 200 l
- Turn on the output for 1 second after every 50 l
- Option cancelled
(1)
The unit of measure depends on the display format chosen.
All examples above are based on the cubic meter format (see point 2.12).
33
. This parameter is identified by the letter "y". This option setting consists of two
r
)
. This parameter is identified by the letter "r". This option setting consists of
n
) - T.A.O.
. This parameter is identified by the letter "n". This option consists of two
.
(1)
(1)
(1)
3200 ET & RM
[y - - - - - 0]
E
[- - - - 10.0]
N
[y - - - OFF]
G
L
[y - - OFF]
I
S
H
[r - - - - 15]
[- - - - - - S]
[r - - - OFF]
[n - - - - 1.0]
[ - - - - 200]
[n - - - - - P]
[- - - - 50]
[n - - - OFF]