Fleck 3200 ET Manual De Uso página 28

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

3 - PROGRAM LEVEL #1
1.4
REGENERATION TIME
Not viewed in meter immediate regeneration mode.
Press the
between the hour set and minute set of numbers. Set the regeneration time with the
set buttons.
Ex.: Regeneration at 2:00 A.M.
1.5
REGENERATION CYCLE PROGRAMMING
The cycle 6 will not be viewed if the cycle 5 is cancelled [5 --- O F F ]. For RM, the cycle 1 will only be
TO
viewed.
1.10
Press the
regeneration cycles. Up to 6 cycles can be programmed. Only a led identifies the four first
display leds. Each display is used to set the duration time (in minute) of that cycle in the
regeneration.
The first display in the series is regeneration cycle 1, example: Backwash
Ex.: Cycle 1 (Backwash): 8 minutes
Cycle 4 (Brine refill): 8.4 minutes (8 min and 24 s.)
EXITING THE LEVEL 1 PROGRAMMING
When the cycle 5 display (or cycle 6 if cycle 5 is activated) is viewed, press once again the
button. The electronics returns in service.
1. Reserve capacity calculation: in meter delayed regeneration mode, the electronic automatically
calculates its reserve capacity based on daily water usage.
2. System capacity and water hardness will not be viewed or set with the timeclock systems or with
the volume override set.
3. The regeneration time will not be viewed or set with the meter immediate regeneration mode.
4. Voltage range for reliable operation of the electronics:
27
button. The red led next to the symbol
button. The next displays are part of a series of option settings used to program the
24V +/- 10%
turns on as well as a non-flashing dot
Installer note:
Frequency: 50/60 Hz
and
[ - - 2 : 0 0 - - ]
[1 - - - 8.0]
[4 - - - 8.4]
3200 ET & RM
E
N
G
L
I
S
H
Tabla de contenido
loading

Este manual también es adecuado para:

3200 rm

Tabla de contenido