3 - PROGRAM LEVEL #2
2.13A
VALVE TYPE (
Not viewed in RM version (Remote Meter).
Press the button
type of valve used with the 3200 ET. There are five possible settings, only the numbers 3 and 4
are used.
Not used
Not used
2510 to 3900 valves. When the number 3 is selected, the 3200 ET timer operate normally, all led
are used. The volume remaining will be able to count down when the valve is back in service.
For 2510 / 2750 / 2850 / 2910 / 3150 / 3900 valves
9000, 9100 and 9500 valves. When the number 4 is selected, the 3200 ET timer operate normally,
all led are used. The volume remaining will be able to count down at the start of the regeneration.
During regeneration, the volume remaining and the regeneration displays will alternate being
viewed: 10 seconds for the regeneration display and 5 seconds for the volume remaining display.
For 9000 / 9100 / 9500 valves
TANK IN SERVICE (
2.13B
Only visible with [ o - - - 4] : for 9000, 9100 and 9500 valves.
Press the button
service (adjusted by the installer).
Ex.: - tank 1 in service
2.14
REGENERATION TYPE (7)
Press the button
regeneration type. There are several possible option settings:
- Timeclock: the electronics determines that regeneration is required when the set regeneration
time has been reached. The regeneration day override setting (see point 2.10) determines the
number of days between two regenerations.
- Meter immediate: the electronics determines that a regeneration is required when the available
volume of softened water drops to zero. The regeneration begins immediately.
- Meter delayed: the electronics determines that a regeneration is required when the available
volume of softened water drops to the reserve capacity. The regeneration begins immediately
at the set regeneration time only when the service flow has not been detected. With service
flow, the regeneration will be delayed in two 10 minute sections. After then if there is always a
flow, the regeneration begins immediately. There will be not a delay if the reserve capacity is
zero.
- Regeneration type 4: not used
Note: for the following options, please contact our customer service.
- Sensor immediate regeneration
- Sensor delayed regeneration
35
o
)
. This parameter is identified by the letter "o". This display is used to set the
o
-4)
. This display is identified by "o-4". This display shows which tank (Unit) is in
. This display is identified by the number "7". This option is used to set the
[o - - - - - 1]
[o - - - - - 2]
[o - - - - - 3]
[o - - - - - 4]
[0 - 4- - - U1]
[7 - - - - - 1]
[7 - - - - - 2]
[7 - - - - - 3]
[7 - - - - - 4]
[7 - - - - - 5]
[7 - - - - - 6]