3 - PROGRAM LEVEL #2
Note:
1. Push the
button once
per display.
2. Option settings may be
changed by pushing the
and
set buttons.
3. Depending on current valve
programming, some
displays will not be
viewed or set.
(1)
The unit of measure depends on the
display format chosen. All examples
above are based on the cubic meter
format. (see point 2.12).
29
2.9.a Time setting for chemical pump (n):
P
Ex.: - Turn on in service for 1 min
- Cancel setting
Note: setting not viewed on timeclock valves.
2.9.b Volume count setting for chemical pump in m
P
Ex.: - Turn on every 0,2 m
2.10. Regeneration day override (A)
P
Ex.: - Override every 7 days
- Cancel setting
Note: in timeclock regeneration, never cancel this setting.
2.11. Volume override (b) in m
P
Ex.: - Regenerate every 80 m
Note: if b is set, water hardness and system capacity are
not viewed.
P
2.12. Display format (U)
Ex.: - US format (Gallon)
- Litre format
- Standard metric
- Cubic meter format
- Japanese metric format
Note: If this parameter is changed, the programming comes
immediately back to the level 1 and directly followed by the
level 2.
Not viewed in RM version.
2.13.a ValveType (o)
P
Ex.: - 2510 - 3900 valves (ET timer)
- 9000, 9100 and 9500 valves (ET timer) [o - - - - - 4]
2.13.b Tank in service indicator (o-4)
P
Note: only viewed for 9000, 9100 and 9500,when "o" set on
4 (see 2.13.a)
Ex.: - Tank 1 in service
2.14 Regeneration type (7)
P
Ex.: - Timeclock
- Meter immediate
- Meter delayed
[n - - - - 1.0]
[n - - - OFF]
3
[- - - - 0.2]
[A - - - - 7]
[A - - OFF]
3 (1)
3
[b - - - 80]
[U - - - - - 1]
[U - - - - - 2]
[U - - - - - 3]
[U - - - - - 4]
[U - - - - - 5]
[o - - - - - 3]
[o - 4 - - U1]
[7 - - - - - 1]
[7 - - - - - 2]
[7 - - - - - 3]
3200 ET & RM
3 (1)
E
N
G
L
I
S
H