8. How to Wire Your Ceiling Fan
If you feel that you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician.
WARNING
!
To avoid possible electrical shock, be sure electricity
is turned off at the main fuse box before wiring.
NOTE: If you are not sure if the outlet box is grounded,
contact a licensed electrician for advice, as it must be
grounded for safe operation.
WARNING
!
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is turned
off at the main fuse box before wiring. All wiring
must be in accordance with National and Local codes
and the ceiling fan must be properly grounded as a
precaution against possible electrical shock.
8.1
Connect the Green Grounding Wire from the Hanger
Ball and the Green Grounding Wire from the Hanger
Bracket to the Grounding Conductor of Supply
(this may be a bare wire or wire with green colored
insulation) (Figure 16). Securely connect Wires using
Wire Connectors supplied.
8.2
Securely connect the Fan Motor White Wire to the
Supply White (neutral) Wire using Wire Connector
supplied (Figure 17).
Securely connect the Fan Motor Black Wire and
Blue Wire to the Supply Black (hot) Wire using Wire
Connector supplied (Figure 17).
After Connections have been made, turn Wires upward
and carefully push Wires into the Outlet Box, with the
White and Green Wires on one side of the Outlet Box
and the Black and Blue Wires on the other side of the
Outlet Box.
WARNING
!
Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until blades are in place. Noise and fan
damage could result.
Figure 16
NOTE: When wiring the ceiling fan for close-to-the-
ceiling mounting, there will be no green grounding
lead from the hanger ball.
!
This product is designed to use only those parts
supplied with this product and/or any accessories
designated specifically for use with this product.
Substitution of parts or accessories not designated
for use with this product by Emerson could result in
personal injury or property damage.
WIRE CONNECTOR
BLACK
SUPPLY (HOT)
BLUE
FAN WIRE
BLACK
FAN WIRE
WHITE SUPPLY
NEUTRAL)
WHITE FAN WIRE
Figure 17
12
SUPPLY
GROUND WIRE
GREEN GROUND
WIRE FROM
HANGER
BRACKET
GREEN GROUND
WIRE FROM
HANGER BALL
WARNING
ETL Model No.: CF717-2