Alarms
Causes
The water flow sensors work
without pressing the filter or heat
button.
After starting or during the
functions of filtering or/and
heating, the water flow sensors
do not detect water flow.
The pump's
thermometer reads the water
temperature below 4°C (40°F).
The pump's thermometer reads
the water temperature over
50°C (122°F).
The pump's
thermometer
connections have issues.
The manual reset thermal
cut-out has a problem.
104°C (219°F) Fuse fault.
Water leakage inside the pump.
Signal line disconnected.
Ground Connection Failed

MAINTENANCE

NOTE: Your spa will require additional air to be added from
time to time. Changes in temperature from day to night will
change the pressure in the spa and may cause a certain
amount of deflation. Please follow the Assembly instructions
and drain the spa before inflating to the accurate pressure
needed.
CAUTION: YOU MUST ENSURE THE PUMP IS UNPLUGGED
BEFORE BEGINNING SPA MAINTENANCE.

Filter Cartridge Maintenance

NOTE: To ensure your spa water stays clean, check and clean your filter cartridges every day-follow
the steps below.
NOTE: We recommend changing your filter cartridges every week. If the filter cartridges remain
soiled and discolored they should be replaced.
Cover Maintenance
The cover shall be cleaned inside and out periodically using a suitable solution that includes adequate
disinfection (e.g. 10 mg/l of Free Chlorine).
Water Maintenance
Many pollutants in the water settle on surfaces below the water line. These pollutants can cause
bacterial, algal or fungal growth. It is recommended that spas are cleaned as regularly as necessary.
After a time, tenacious stains or biofilms may develop on the accessible surfaces below the water line
or high concentrations of salts or unwanted reaction by-products may also occur. Depending on
hygienic condition, cleanliness, visibility, odour, debris and stains, it is recommended to change the
water completely and clean/disinfect the spa. When emptying the spa, the regulations and the
303021213751_14x21cm_54138;54173_欧规HydroJet SPA说明书_英
Reasons
1. The water flow sensor flags didn't fall back
into the correct position.
2. The water flow sensors are broken.
1. You forgot to remove the 2 stopper caps from
inside the pool.
2. The filter cartridges are dirty.
3. Activate the filter or heat system and put your hand
in front of the outlet pipe inside the pool to check if
you can feel water. flowing out.
a. If no water flows out the water pump is broken.
b. Water flows out but the alarm
appears, the
water flow sensors are broken.
1. The water temperature is lower than 4°C (40°F).
2. If the water temperature is higher than
7°C (44.6°F), the pump's thermometer is broken.
1. The water temperature is over 50°C (122°F).
2. If the water temperature is lower than
45°C (113°F), the pump's thermometer is broken.
1. The pump's thermometer connectors are not
working properly.
2. The pump's thermometer is broken.
The manual reset thermal cut-out has been tripped.
The fuse is disconnected.
The system has detected some water leakage inside
the pump.
The signal line between control panel and power
board is not well connected.
1. The ground bonding of your home has some problem.
2. The pump has some problem.
Filter Set
Filter Cartridge 58323
16
Solutions
1. Unplug the pump, strike the side of the pump firmly (but not violently), and plug
it back in.
2. To get assistance visit our website www.bestwaycorp.com support section
1. Remove the two stopper caps before starting the heating system. Refer to the
Assembly section in the User's Manual.
2. Remove the filter set from inside the pool and push the filter or heat button. If no
alarm appears, clean or change the filter cartridges and re-install the filter set
inside the pool.
3. To get assistance visit our website www.bestwaycorp.com support section
1. The spa is not designed to operate with water temperatures lower than 4ºC (40°F).
Unplug the pump and only re-start the pump when the water temperature reaches
6°C (43°F).
2. To get assistance visit our website www.bestwaycorp.com support section
1. The spa is not designed to operate with water temperatures greater than
40°C (104°F). Unplug the pump and only re-start the pump when the water
temperature reaches 38°C (100°F) or lower.
IMPORTANT: Before you re-start the pump, push the pump's reset button.
2. To get assistance visit our website www.bestwaycorp.com support section
To get assistance visit our website www.bestwaycorp.com support section
1. Unplug the pump and push the reset button, then plug the pump back in.
2. In case the alarm still remains, check the RESET BUTTON section in manual.
3. To get assistance visit our website www.bestwaycorp.com support section
To get assistance visit our website www.bestwaycorp.com support section
To get assistance visit our website www.bestwaycorp.com support section
To get assistance visit our website www.bestwaycorp.com support section
To get assistance visit our website www.bestwaycorp.com support section

Capítulos

Tabla de contenido
loading

Tabla de contenido