Nice One OXI family Instrucciones Y Advertencias Para La Instalación Y El Uso página 20

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 63
EN
SIGNALS EMITTED BY THE
–– Long flashes / GREEN ––
On start-up:
1 5 = Code in use: "Flo"
2 5 = Code in use: "O-Code"/"FloR"
3 5 = Code in use: "Smilo"
5 5 = No remote control memorised
During operation:
1 5 = Indicates that the code received is not stored in the
memory
1 5 = During programming, indicates that the code is
already stored in the memory
3 5 = Saving code in memory
5 5 = Memory deleted
6 5 = During programming, indicates that the code is not
authorised for memorisation
8 5 = Memory full
––––––––––––––––––––––––––––––––––––––––––––––––––
–– Short flashes / GREEN ––
1 5 = "Certificate" not valid for memorisation
2 5 = Code cannot be memorised as is transmitting
"certificate"
3 5 = During programming, indicates that the code has
20
Table A
RECEIVER LED
been re-synchronised
4 5 = Output in "Mode II" not managed on control unit
5 5 = During deletion procedure, indicates that the code
has been deleted
5 5 = "Certificate" with higher priority that the admissible
value
6 5 = Code synchronisation failure
6 5 = Code cannot be memorised due to "incorrect key"
––––––––––––––––––––––––––––––––––––––––––––––––––
–– Long flashes / RED ––
1 5 = Non-original code block
2 5 = Code with lower priority than the authorised value
––––––––––––––––––––––––––––––––––––––––––––––––––
–– Short flashes / RED ––
1 5 = "In vicinity" programming mode block
1 5 = Memorisation by means of "certificate" block
2 5 = Memory block (PIN entry)
––––––––––––––––––––––––––––––––––––––––––––––––––
–– Long flashes / ORANGE ––
1 5 = Indicates that the code is in the memory but
outside the group currently enabled
––––––––––––––––––––––––––––––––––––––––––––––––––
–– Short flashes / ORANGE ––
2 5 = Indicates activation of block programming
(on start-up)
Tabla de contenido
loading

Este manual también es adecuado para:

One ox2 family

Tabla de contenido