TECHNICAL DATA

DESCRIPTION
Category
Country of destination
Category
Country of destination
Type of appliance
Heating
Nominal heat input (Hi)
Nominal heat output (80-60°C)
Nominal heat output (50-30°C)
Reduced heat input (Hi)
Reduced heat output (80-60°C)
Reduced heat output (50-30°C)
Domestic hot water
Nominal heat input (Hi)
Nominal heat output (*)
Reduced heat input (Hi)
Reduced heat output (*)
Useful effi ciency Pn max - Pn min (80°-60°)
Useful effi ciency Pn max - Pn min (50°-30°)
Useful effi ciency 30% (47° return)
Useful effi ciency 30% (30° return)
Combustion effi ciency
Electric power
Circulator electric power (1.000 l/h)
Power supply voltage
Electrical protection
Pressure drops on fl ue with burner on
Pressure drops on fl ue with burner off
Residual head of concentric pipes 0.85m ø 60-100
Residual head of separate pipes 0.5m ø 80
Residual head of boiler without pipes
Heating operation
Maximum pressure
Maximum temperature
Minimum pressure for standard operation
Selection fi eld of heating water temperature
Pump: maximum head available
for system capacity
Membrane expansion tank
Expansion tank pre-charge
DHW operation
Maximum pressure
Minimum pressure
Quantity of hot water with ∆t 25°C
with ∆t 30°C
with ∆t 35°C
DHW minimum capacity
Selection fi eld of domestic hot water temperature
Flow regulator
NOx class
Gas pressure
Methane gas nominal pressure (G20 - I2H)
LPG liquid gas nominal pressure (G31 - I3P)
Hydraulic connections
Heating input-output
DHW input-output
Gas input
Boiler dimensions
Height
Width
Depth of housing
Boiler weight
Flow rate
Air capacity
kW
kcal/h
kW
kcal/h
kW
kcal/h
kW
kcal/h
kW
kcal/h
kW
kcal/h
kW
kcal/h
kW
kcal/h
kW
kcal/h
kW
kcal/h
%
%
%
%
%
W
W
V - Hz
IP
%
%
Pa
Pa
Pa
bar
°C
bar
°C
mbar
l/h
l
bar
bar
bar
l/min
l/min
l/min
l/min
°C
l/min
mbar
mbar
Ø
Ø
Ø
mm
mm
mm
kg
G20
Nm
3
G31
25 C.S.I.
II2H3P
I3P
B22P, B52P; C12,C12x; C22; C32,C32x; C42,C42x; C52,C52x; C82,C82x; C92,C92x
25,00
21.500
24,35
20.941
25,90
22.274
15,00
12.900
14,25
12.255
14,85
12.771
25,00
21.500
25,00
21.500
9,50
8.170
9,50
8.170
97,4-95,0
103,6-99,0
95,2
100,1
97,5
129
39
230-50
X5D
2,47
0,09
25
108
140
3
90
0,25-0,45
40-80
266
1.000
8
1
6
0,15
14,3
11,9
10,2
2
37-60
10
2
20
37
3/4"
1/2"
3/4"
780
400
332
39
CH
39,660
/h
40,208
Mynute Sinthesi C.S.I.
Mynute Sinthesi
29 C.S.I.
II2H3P
(+)
CY-MT
24.940
24.341
25.738
12.900
12.281
12.681
24.940
24.940
97,6-95,2
103,2-98,3
230-50
0,25-0,45
DHW
CH
39,660
44,172
40,208
43,393
I3P
29,00
28,30
29,93
15,00
14,28
14,75
29,00
29,00
9,90
8.514
9,90
8.514
95,8
99,5
97,7
114
39
X5D
2,29
0,08
20
100
130
3
90
40-80
266
1.000
9
1
6
0,15
16,6
13,9
11,9
2
37-60
12
2
20
37
3/4"
1/2"
3/4"
780
450
332
42
DHW
44,172
43,393
13
Tabla de contenido
loading

Este manual también es adecuado para:

Mynute sinthesic 29 c.s.i.Mynute sinthesi 29 c.s.i

Tabla de contenido