Mount the Light Control
1. Place the mounting bolt through the front of the
junction box cover. Push the small gasket hole over
the mounting screw.
2. Make sure the wire connectors and wires are inside
the junction box. Align the mounting screw with the
center hole in the mounting strap.Secure the fixture
to the mounting strap.
3. Push the rubber plug firmly into place.
4. Not intended for waterproof junction boxes. Fixture
should be surface mount only. Caulk the wall plate
mounting surface with silicone weather sealant.
Lamp Shade
Lock Nuts
Lens
CAUTION: To avoid water damage and electrical
shock, keep lamp holders 30° below horizontal.
5. Adjust the lamp holders by loosening the lock nuts
but do not rotate the lamp holders more than 180°
from the factory setting.
6. Adjust lamp shades by loosening the set screws
several turns, turn shades counterclockwise and
remove.Reinstall the shades in the desired position
and tighten set screws.
Screw
Push the Rubber Plug
over the Mounting Screw.
Set Screw
Keep lamps at
least 2" (51 mm)
from the sensor.
TEST AND ADJUSTMENT
1. Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1
before it will detect motion. When first turned
on, wait 1
/
1
2
2. Turn the RANGE control to the minimum position
(MIN), D
B
to OFF, and the ON-TIME control
®
ual
rite
to the TEST position.
LAMP MODE
NORMAL SOFT FLASH
ON-TIME
MIN
MAX
TEST 1 5 20
RANGE
MINUTES
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where pets or unwanted traffic may trigger
the control.
• Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
8 ft.
(2.4 m)
70 ft.
(21 m)
Maximum Range
4
/
minute warm up period
1
2
minutes.
DUAL BRITE™
OFF 3 6 DUSK TO
HOUR
DAWN
100 ft.
(30.5 m)
Boosted
Maximum
Coverage Angle
598-1309-02
270°