3. Ceiling Fan Assembly
3.9
IMPORTANT: THE SIDE OF THE FAN BLADE
HAVING THE RIB LINE MUST BE FACING
UPWARDS AS SHOWN IN FIGURE 8.
Mount the Blade Flange to the Fan Blade using Three
M5 x 6mm Washer Head Screws (supplied) (Figure 8).
Repeat this procedure for other Four Fan Blades and Blade
Flanges.
WARNING
!
To reduce the risk of personal injury, do not bend
the blade flange when installing the blade flanges,
balancing the blades or cleaning the fan. Do not insert
foreign objects in between rotating fan blades.
3.10
Rotate the Motor Hub until the Flange Screw Hole is next to
the cutout in the Switch Housing Plate.
Attach One Blade Assembly to the Motor Hub using Two
M6 x 14mm Flange Screws with Lockwashers Preassembled
in Flange (Figure 9).
Make sure the Screws are NOT tightened.
Repeat this procedure for the other Four Blade Assemblies.
NOTE: The blade flanges have an interlocking
feature that must be fully engaged before
tightening the screws. Make sure all the flanges
are properly engaged and then tighten the flange
screws. If one of the flanges does not seat properly
on the motor hub, loosen the adjacent flange
screws, re-engage and reseat the flanges, then
tighten the screws again.
A spare M6 x 14mm Flange Screw with Lockwasher is in the
hardware bag, if needed.
(Continued)
M5 x 6mm WASHER HEAD
BLADE SCREW (3)
RIB LINE
(facing up)
BLADE FLANGE
Figure 8
M6 x 14 FLANGE SCREWS
WITH LOCKWASHERS
(2 preassembled
blade/flange
assemblies)
Figure 9
8
FAN
BLADE
MOTOR
HUB
SWITCH
HOUSING
PLATE
U.L. Model No.: CF652